3. Detecting temperature increase at the center
of the top of the PDP panel and shutting it
down
Service Mode
General
Fan Status
Fan Control
Ref Voltage
F/B Voltage
Drive Data
P/S Temp
Center Temp
I/O Block Temp : 43[dC]
Left Temp
(1) Center Temp : The temperature that is measured by
the S board installed in the top of the
power supply board, is displayed. If
temperature exceeds 69dC, the Standby
indicator flashes at the interval of 0.4
seconds continuously. If temperature
exceeds 74dC, the shutting-down is
activated.
4. Detecting temperature increase at the I/O
block side of the top of the PDP panel and
shutting it down
Service Mode
General
Fan Status
Fan Control
Ref Voltage
F/B Voltage
Drive Data
P/S Temp
Center Temp
I/O Block Temp : 43[dC]
Left Temp
(1) I/O Block Temp : The temperature that is measured
by the S board installed in the top
of the Q block assembly, is dis-
played. If temperature exceeds
61dC, the Standby indicator flashes
at the interval of 0.4 seconds
continuously. If temperature
exceeds 66dC, the shutting-down is
activated.
PFM-32C1/32C1E
:
Auto
:
8.5[V]
:
8.5[V]
2B5F
: 43[dC]
: 43[dC]
(1)
: 43[dC]
:
Auto
:
8.5[V]
:
8.5[V]
2B5F
: 43[dC]
: 43[dC]
(1)
: 43[dC]
5. Detecting temperature increase at the left side
of the PDP panel and shutting it down
Service Mode
General
Fan Status
Fan Control
Ref Voltage
F/B Voltage
Drive Data
P/S Temp
Center Temp
I/O Block Temp : 43[dC]
Left Temp
(1) Left Temp : The temperature that is measured by the
S board installed in the vicinity of the fan
(large), is displayed. If temperature
exceeds 67dC, the Standby indicator
flashes at the interval of 0.4 seconds
continuously. If temperature exceeds
72dC, the shutting-down is activated.
:
Auto
:
8.5[V]
:
8.5[V]
2B5F
: 43[dC]
: 43[dC]
: 43[dC]
(1)
3-3