Cost-effective HD IR Waterproof Fixed IP Camera Quick Start Guide Version 1.0.1...
Page 2
Welcome Thank you for purchasing our IP camera! This quick start guide is designed to be a reference tool for your system. Please keep this start guide well for future reference. Please open the accessory bag to check the items one by one in accordance with the list below. Contact your local retailer ASAP if something is missing or damaged in the bag.
Page 3
The grounding studs of the product are recommended to be grounded to further enhance the reliability of the camera. 6. Daily Maintenance Please shut down the device and then unplug the power cable before you begin daily maintenance work. Do not touch the CCD (CMOS) optic component. You can use the blower to clean the dust on the lens surface.
Page 5
You can refer to the following figure for multiple-function combination cable information. See Figure 1-1 Figure 1-1 Please refer to the following sheet for detailed information. Port Name Function Connection Note Ethernet 1.LAN Network port Connect to standard Ethernet cable. port Power input...
Page 7
Please follow the steps listed below to install the device. Please refer to Figure 2-1 and Figure 2-2 for reference. Paste the installation map on the surface of the wall or the ceiling. Dig the installation holes according to the installation map. Open the accessories bag and then take the expansion bolt out.
Page 9
Quick configuration tool can search current IP address, modify IP address. At the same time, you can use it to upgrade the device. Please note the tool only applies to the IP addresses in the same segment. Double click the “ConfigTools.exe” icon; you can see an interface is shown as in Figure 3-1. In the device list interface, you can view device IP address, port number, subnet mask, default gateway, MAC address and etc.
Figure 3-2 Select the “Open Device Web” item; you can go to the corresponding web login interface. See Figure 3-3. Figure 3-3 If you want to modify the device IP address without logging in the device web interface, you can go to the configuration tool main interface to set.
Page 11
Figure 3-4 After you logged in, the configuration tool main interface is shown as below. See Figure 3-5. Figure 3-5 For detailed information and operation instruction of the quick configuration tool, please refer to the Quick Configuration Tool User’s Manual included in the resources CD.
Page 12
I can not boot up Please click RESET button for at least five seconds to restore the device or factory default setup. operate properly. The water leakage The unauthorized front or rear cap remove many result in water occurred. leakage. The glass front cap has sustained heavy push or strike.
Page 13
Component Name Toxic or Hazardous Materials or Elements Cr VI PBDE Circuit Board Component Device Construction Material Wire and Cable Packing Components Accessories O: Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ/T11363-2006 standard. X: Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ/T11363-2006 standard.
Page 14
Cost-effective HD IR Waterproof Fixed IP Camera User’s Manual Version 1.0.2...
Page 15
Welcome Thank you for purchasing our IP camera! This user’s manual is designed to be a reference tool for your system. Please read the following safeguard and warnings carefully before you use this series product! Please keep this user’s manual well for future reference!
Page 16
Important Safeguards and Warnings 1 Electrical safety All installation and operation here should conform to your local electrical safety codes. The power shall conform to the requirement in the SELV (Safety Extra Low Voltage) and the Limited power source is rated 12V DC in the IEC60950-1.This series product supports PoE too. Please note: Do not connect these two power supplying sources to the device at the same time;...
Page 17
Do not touch the CCD (CMOS) optic component. You can use the blower to clean the dust on the lens surface. Always use the dry soft cloth to clean the device. If there is too much dust, please use the water to dilute the mild detergent first and then use it to clean the device.
Page 19
This series IP camera integrates the traditional camera and network video technology. It adopts video data collection, transmission together. It can connect to the network directly without any auxiliary device. This series IPC uses standard H.264 video compression technology, which maximally guarantees the video quality.
Page 20
Please refer to the following sheet for IPC performance specification. Model IPC-HFW2100P/N Series Parameter Main Processor TI Davinci high performance DSP Embedded LINUX System Support real-time network, local record, and remote operation at the Resources same time. User Interface Remote operation interface such as WEB, DSS, PSS System Status Bit stream statistics, log, and software version.
Page 22
You can refer to the following figure for multiple-function combination cable information. See Figure Figure 2-1 Please refer to the following sheet for detailed information. Port Name Function Connection Note Ethernet 1.LAN Network port Connect to standard Ethernet cable. port Power input 2.DC12V...
Page 24
Please follow the steps listed below to install the device. Please refer to Figure 3-1 and Figure 3-2 for reference. Paste the installation map on the surface of the wall or the ceiling. Dig the installation holes according to the installation map. Open the accessories bag and then take the expansion bolt out.
Page 26
Quick configuration tool can search current IP address, modify IP address. At the same time, you can use it to upgrade the device. Please note the tool only applies to the IP addresses in the same segment. Double click the “ConfigTools.exe” icon; you can see an interface is shown as in Figure 4-1. In the device list interface, you can view device IP address, port number, subnet mask, default gateway, MAC address and etc.
Page 27
Figure 4-2 Select the “Open Device Web” item; you can go to the corresponding web login interface. See Figure 4-3. Figure 4-3 If you want to modify the device IP address without logging in the device web interface, you can go to the configuration tool main interface to set.
Page 28
Figure 4-4 After you logged in, the configuration tool main interface is shown as below. See Figure 4-5. Figure 4-5 For detailed information and operation instruction of the quick configuration tool, please refer to the Quick Configuration Tool User’s Manual included in the resources CD.
Page 29
I can not boot up Please click RESET button for at least five seconds to restore the device or factory default setup. operate properly. The water leakage The unauthorized front or rear cap remove many result in water occurred. leakage. The glass front cap has sustained heavy push or strike.
Page 30
Toxic or Hazardous Materials or Elements Component Name Cr VI PBDE Circuit Board Component Device Construction Material Wire and Cable Packing Components Accessories O: Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ/T11363-2006 standard. X: Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ/T11363-2006 standard.
Page 33
4.2.11 WIFI.........................30 4.2.12 Qos........................32 ..........................33 4.3.1 Video detect ......................33 4.3.2 Alarm........................38 4.3.3 Abnormity ......................40 .........................42 4.4.1 Record schedule and snapshot schedule ............42 4.4.2 Destination ......................43 4.4.3 Record control ......................45 ..........................46 4.5.1 General ........................46 4.5.2 Account........................49 4.5.3 PTZ.........................53 4.5.4 Default........................53 4.5.5 Import/Export ......................54 4.5.6 Auto maintenance ....................54 4.5.7 Firmware update ....................55 ........................55...
Page 34
This series IPC product support the Web access and management via PC. Web includes several modules includes monitor channel preview, PTZ control, system configuration, alarm and etc. Please follow the steps listed below for network connection. Make sure the IPC has connected to the network properly. IPC IP address and PC IP address shall be in the same network segment.
Open IE and input IP camera address in the address bar. For example, if your camera IP is 192.168.1.108, then please input http:// 192.168.1.108 in IE address bar. See Figure 2-1. Input your IP address here Figure 2-1 IE The login interface is shown as below. See Figure 2-2. Please input your user name and password.
Page 36
Figure 2-2 Login Interface If it is your first time to login in, system pops up warning information to ask you whether install control webrec.cab or not. Please click OK button, system can automatically install the control. When system is upgrading, it can overwrite the previous Web too.
Page 37
After you logged in, you can see the live monitor window. See Figure 2-4. Figure 2-4 Live Interface There are four sections: Section 1: Encode setup bar Section 2: System menu Section 3: Window function option bar Section 4: Window adjust bar The encode setup interface is shown as in Figure 2-5.
Page 38
Figure 2-5 Encode setup Please refer to the following sheet for detailed information. Parameter Function In normal network width environment, main stream can record Main stream audio/video file and realize network monitor. You can set the main stream resolution if your device supports. If network width is not sufficient, you can use sub stream to Sub (Extra) realize network monitor.
Page 39
You can snapshoot important video. All images are Snapshot memorized in system folder: \ picture download (default). You can go to Setup->Camera->Video->Path to modify the local record save path. When you click local record button, the system begins Record recording. The recorded file is saved to system folder: \ RecordDownload(default).
Page 40
Figure 2-9 Please refer to the following sheet for detailed information. Parameter Function Video It is to adjust monitor video Note: setup brightness. All the operations here apply to WEB end It is to adjust monitor video contrast only. ness. Please go to Setup- >Camera->Conditions It is to adjust monitor video...
Page 41
Before PTZ operation, please make sure you have properly set PTZ protocol. (Please go to Setup- >System->PTZ to set.). Here you can view direction keys, speed, zoom, focus, iris, preset, tour, pan, scan, pattern, aux close, and PTZ setup button. See Figure 3-1. PTZ direction: PTZ supports eight directions: left/right/up/down/upper left/upper right/bottom left/bottom right.
Page 42
Figure 3-2 PTZ Setup Please refer to the following sheet for PTZ setup information. Parameter Function Move the camera to you desired location and then click left limit Scan button. Then move the camera again and then click right limit button to set a right limit.
Page 43
Parameter Function You can input pattern value and then click start record button to Pattern begin PTZ movement. Please go back to Figure 3-1 to implement camera operation. Then you can click stop record button in Figure 3-2. Now you have set one pattern. The assistant items include: BLC, Digital zoom, night vision, camera Assistant brightness, flip.
4.1.1 Conditions Here you can view device property information. Slight differences may be found due to different IPC series. The setups become valid immediately after you set. See Figure 4-1. Figure 4-1 Please refer to the following sheet for detailed information. Parameter Function Brightness...
Page 45
Contrast It is to adjust monitor window contrast. The value ranges from 0 to 100. The default value is 50. The larger the number, the higher the contrast is. You can use this function when the whole video bright is OK but the contrast is not proper.
Page 46
Auto Iris Before the setup, please make sure you have installed the auto iris. You can check the box before ON to enable this function. The auto iris may change if the light becomes different. When you disable this function, the iris is at the max. System does not add the auto iris function in the exposure control.
4.1.2 Video 4.1.2.1 Video bit stream The video bit stream interface is shown as below. See Figure 4-2. Figure 4-2 Please refer to the following sheet for detailed information. Parameter Function It includes general stream, motion stream and alarm Main Bit stream type stream.
Page 48
Parameter Function There are three options: H.264(main profile standard, Encode mode H.264B(baseline standard encode and MJPG encode. The H.264 and H.264B both are H264 bit stream. H.264 is the Main Profile encode and the H.264B is the Baseline Profile encode mode. H.264B is for Blackberry cell phone to realize the monitor.
Page 49
Parameter Function There are three options: H.264(main profile standard, Encode mode H.264B(baseline standard encode and MJPG encode. The H.264 and H.264B both are H264 bit stream. H.264 is the Main Profile encode and the H.264B is the Baseline Profile encode mode. H.264B is for Blackberry cell phone to realize the monitor.
Page 50
Figure 4-3 Please refer to the following sheet for detailed information. Parameter Function There are two modes: general (schedule) and Event Snapshot type (activation). Image size It is the same with the resolution of the main stream. It is to set the image quality. There are six levels. Quality It is to set snapshot frequency.
Parameter Function Privacy mask Here you can privacy mask the specified video in the monitor video. System max supports 4 privacy mask zones. Time Title You can enable this function so that system overlays time information in video window. You can use the mouse to drag the time tile position. Channel Title You can enable this function so that system overlays channel information in video window.
Figure 4-6 Please refer to the following sheet for detailed information. Parameter Function Audio enable Main stream: Recorded file only contains video by default. You need to check the audio box here to enable audio function. Sub (Extra) stream: Recorded file only contains video by default.
Page 53
Figure 4-7 Please refer to the following sheet for detailed information. Parameter Function Host Name It is to set current host device name. It max supports 32-digit character. Ethernet Card Please select the Ethernet port. It is for the wire LAN by default. Please note for the -W series product, it has the wireless network card, and you can modify the default Ethernet port setup.
IP Version It is to select IP version. IPV4 or IPV6. You can access the IP address of these two version. IP Address Please use the keyboard to input the corresponding number to modify the IP address and then set the corresponding subnet mask and the default gateway.
Page 55
Figure 4-8 Please refer to the following sheet for detailed information. Parameter Function It is the max Web connection for the same device. The value ranges from 1 connection to 20. The max connection amount is 20. TCP port The default value is 37777. You can input the actual port number if necessary.
4.2.3 PPPoE The PPPoE interface is shown as in Figure 4-9. Input the PPPoE user name and password you get from the IPS (internet service provider) and enable PPPoE function. Please save current setup and then reboot the device to get the setup activated. Device connects to the internet via PPPoE after reboot.
Figure 4-10 Please refer to the following sheet for detailed information. Parameter Function Server Type You can select DDNS protocol from the dropdown list and then enable DDNS function. The private DDNS protocol means you use your self-defined private protocol to realize DDNS function. Server IP DDNS server IP address Server Port...
Please refer to the following sheet for detailed information. Parameter Function Input server address and then enable this function. SMTP Server Port Default value is 25. You can modify it if necessary. Anonymity For the server supports the anonymity function. You can auto login anonymously.
Here you can also add, modify or remove UPnP item. See Figure 4-13. In the Windows OS, From Start->Control Panel->Add or remove programs. Click the “Add/Remove Windows Components” and then select the “Network Services” from the Windows Components Wizard. Click the Details button and then check the “Internet Gateway Device Discovery and Control client” and “UPnP User Interface”.
Page 61
Figure 4-14 Please refer to the following sheet for detailed information. Parameter Function System only processes the information of V1. SNMP V1 SNMP V2 System only processes the information of V2. SNMP Port The listening port of the proxy program of the device. It is a UDP port not a TCP port.
Parameter Function The destination port of the Trap information from the proxy Trap port program of the device. It is for the gateway device and the client-end PC in the LAN to exchange the information. It is a non-protocol connection port. It has no effect on the network applications.
Page 63
can just send out one data to transit. This function also depends on the relationship of the group member and group of the outer. Here you can set multicast address and port. You also need to go to Live interface to set the protocol as Multicast.
Page 64
Figure 4-17 Please check the box to enable WIFI function and then click the Search SSID button. Now you can view all the wireless network information in the following list. Double click a name to connect to it. See Figure 4-18.
Page 65
Figure 4-18 4.2.12 Qos The QoS interface is shown as below. See Figure 4-19. Qos (Quality of Service) is network security mechanism. It is a technology to fix the network delay and jam problem and etc. For the network service, the quality of service includes the transmission bandwidth, delay, the packet loss and etc.
Page 66
Figure 4-19 Please refer to the following sheet for detailed information. Parameter Function Real-time The value ranges from 0 to 63. The router or the switcher can monitor provide different service for various data packets. Command The value ranges from 0 to 63. The router or the switcher can provide different service for various data packets.
Page 68
Figure 4-22 Please refer to the following sheet for detailed information. Parameter Function Enable You need to check the box to enable motion detection function. There are six levels. The sixth level has the highest sensitivity. Sensitivity Region There are six levels. The sixth level has the highest sensitivity. Region: If you select motion detection type, you can click this button to set motion detection zone.
Page 69
Parameter Function System only memorizes one event during the anti-dither period. Anti-dither The value ranges from 0s to 100s. Relay out Enable alarm activation function. You need to select alarm output port so that system can activate corresponding alarm device when alarm occurs.
Page 70
Figure 4-24 Please refer to the following sheet for detailed information. Parameter Function Enable You need to check the box to enable this function. There are six levels. The sixth level has the highest sensitivity. Sensitivity Area There are six levels. The sixth level has the highest sensitivity. Region: you can click this button to set Video masking zone.
Page 71
Parameter Function Relay out Enable alarm activation function. You need to select alarm output port so that system can activate corresponding alarm device when alarm occurs. System can delay the alarm output for specified time after alarm Alarm Delay ended. The value ranges from 10s to 300s. Record System auto activates motion detection channel to record once channel...
Page 72
Please refer to the following sheet for detailed information. Parameter Function Enable You need to check the box to enable this function. Working This function becomes activated in the specified periods. Period There are six periods in one day. Please draw a circle to enable corresponding period.
Page 73
Figure 4-26 Please refer to the following sheet for detailed information. Parameter Function Alarm output There is only one output channel. Please click the button 1. If you want to enable the alarm activation output function, please press the corresponding button and then trigger. Search alarm output status.
Page 75
Figure 4-31 Please refer to the following sheet for detailed information. Parameter Function Event The abnormal events include: no disk, no space, disk error, net error, Type offline, IP conflict. Threshold: You can set the minimum percentage value here. The device can alarm when capacity is not sufficient.
Page 76
There are three record modes: general (auto), motion detect and alarm. There are six periods in one day. Please make sure you have enabled the corresponding record mode in the Setup->Storage- >Conditions. You can view the current time period setup from the color bar. Green color stands for the general record/snapshot.
Page 77
Parameter Function Event It includes: general, motion detect and alarm. Type Local It saved in the SD card. It saved in the FTP server. Network It can save according to the corresponding network protocol. The local interface is shown as in Figure 4-34. Here you can view local SD card or disk information. You can also operate the read-only, write-only, hot swap and format operation.
Page 78
Figure 4-35 The network interface is shown as in Figure 4-36. You need to check the box to enable the network. Please select the mode from the dropdown list. It includes: NFS, ISCSI and etc. You can select according to your actual requirements. Figure 4-36 4.4.3 Record control The record control interface is shown as in Figure 4-37.
Page 79
Figure 4-37 Please refer to the following sheet for detailed information. Parameter Function Here you can select file size. Default setup is 8 minutes. Pack Duration Pre-record Please input pre-record value here. For example, system can record the four seconds video in the buffer. The record begins from the fifth second.
Page 80
Figure 4-38 Please refer to the following sheet for detailed information. Parameter Function It is to set device name. Device No Video This is to display video standard such as PAL. Standard Language You can select the language from the dropdown list. Please note the device needs to reboot to get the modification activated.
Page 81
Figure 4-39 Please refer to the following sheet for detailed information. Parameter Function Here you can select date format from the dropdown list. Date format There are two options: 24-H and 12-H. Time Format The time zone of the device. Time zone It is to set system time.
Page 82
4.5.2 Account Note: For the character in the following user name or the user group name, system max supports 6-digits. The space in the front or at the end of the string is null. The valid string includes: character, number, and underline.
Page 83
Figure 4-41 Modify user It is to modify the user property, belonging group, password and rights. See Figure 4-42. Modify password It is to modify the user password. You need to input the old password and then input the new password twice to confirm the new setup.
Page 84
Figure 4-42 4.5.2.2 Group The group management interface can add/remove group, modify group password and etc. The interface is shown as in Figure 4-43. Figure 4-43 Add group: It is to add group and set its corresponding rights. See Figure 4-45.
Page 85
Please input the group name and then check the box to select the corresponding rights. It includes: shutdown/reboot device, live view, record control, PTZ control and etc. Figure 4-44 Modify group Click the modify group button, you can see an interface is shown as in Figure 4-45. Here you can modify group information such as remarks and rights.
Page 86
4.5.3 PTZ The PTZ interface is shown as in Figure 4-46. Figure 4-46 Please refer to the following sheet for detailed information. Parameter Function Select the corresponding dome protocol. Protocol Set corresponding dome address. Default value is 1. Please note your Address setup here shall comply with your dome address;...
Page 87
Figure 4-47 4.5.5 Import/Export The interface is shown as in Figure 4-48. Figure 4-48 Please refer to the following sheet for detailed information. Parameter Function It is to import the local setup files to the system. Import It is to export the corresponding system setup to your local PC. Export 4.5.6 Auto maintenance The auto maintenance interface is shown as in Figure 4-49.
Page 88
Figure 4-49 4.5.7 Firmware update The firmware interface is shown as in Figure 4-50. Please select the upgrade file and then click the update button to begin firmware update. Important Update improper program may result in device malfunction! Figure 4-50 4.6.1 Version The version interface is shown as in Figure 4-51.
Page 89
Figure 4-51 4.6.2 Log Here you can view system log. See Figure 4-52. Figure 4-52 Please refer to the following sheet for log parameter information. Parameter Function Log types include: system operation, configuration operation, data Type operation, event operation, record operation, user management, log clear.
Page 90
Parameter Function Set the end time of the requested log. End time You can select log type from the drop down list and then click search Search button to view the list. You can click the stop button to terminate current search operation. You can select one item to view the detailed information.
Page 91
Click alarm function, you can see an interface is shown as in Figure 5-1. Here you can set device alarm type and alarm sound setup. Figure 5-1 Alarm Please refer to the following sheet for detailed information. Type Parameter Function Alarm Motion detection System alarms when motion detection alarm...
Page 92
Click log out button, system goes back to log in interface. See Figure 6-1. Figure 6-1 Note Slight difference may be found in user interface. All the designs and software here are subject to change without prior written notice. If there is any uncertainty or controversy, please refer to the final explanation of us. Please visit our website for more information.
Page 94
ClearView POWERED BY C l e a r C h o i c e ClearView CCTV products are professional quality equipment, and we stand behind our products with a 7 Year Warranty. ClearView CCTV will replace, or at its sole discretion repair without charge, any DVR (Digital Video Recorder), NVR (Network Video Recorder) Camera or accessory proved defective in material, workmanship or operation for a period of seven (7) years, subject to warranty conditions and exceptions below.