free hit counter

Design Guideline Summary; Refrigerant Piping Design - LG LA090HYV1 Engineering Manual

Single zone art cool premier wall mounted
Hide thumbs Also See for LA090HYV1:
Table of Contents

Advertisement

reFrigerAnT PiPing deSign

design Guideline Summary/Selecting Field-Supplied copper tubing
device Connection limitations
Single-zone systems consist of one outdoor unit and one indoor
unit. one of the most critical elements of a single zone system is
the refrigerant piping. Table 16 lists pipe length limits that must be
followed in the design of a Single Zone Art Cool Premier refrigerant
pipe system. Refer to Figure 16 for maximum length and elevation of
piping.
Table 14: Single-Zone Art Cool Premier Wall-Mount Refrigerant Piping System Limitations.
Pipe Length
(ELF = Equivalent Length of
pipe in Feet)
Elevation
(All Elevation Limitations are
Measured in Actual Feet)
Additional Refrigerant needed (oz/ft)
Table 15: Linear Thermal Expansion of Copper Tubing in Inches.
Pipe
Length
1
35°
40°
45°
10
0.04
0.04
0.05
20
0.08
0.08
0.10
30
0.12
0.12
0.15
40
0.16
0.16
0.20
50
0.20
0.20
0.25
60
0.24
0.24
0.30
Pipe length baseline temperature = 0°F. "Expansion of Carbon, Copper and Stainless Steel Pipe," The Engineers' Toolbox, www.engineeringtoolbox.com.
1
38 | reFrIGerant deSIGn
Longest total equivalent piping length
Shortest total equivalent piping length
Distance between fittings and indoor units
or outdoor units
If outdoor unit is above indoor unit
If outdoor unit is below indoor unit
50°
55°
60°
65°
70°
0.06
0.06
0.07
0.08
0.08
0.12
0.13
0.14
0.15
0.16
0.18
0.20
0.21
0.23
0.24
0.24
0.26
0.28
0.30
0.32
0.30
0.33
0.35
0.38
0.40
0.36
0.39
0.42
0.45
0.48
Due to our policy of continuous product innovation, some specifications may change without notification.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG " is a registered trademark of LG Corp.
Figure 16: Art Cool Premier System Layout.
Indoor unit
A
B
Outdoor unit
LA090HYV1
65.6 feet
6.6 feet
≥20 inches
32.8 feet
32.8 feet
0.22
Fluid Temperature °F
75°
80°
85°
90°
95° 100° 105° 110° 115° 120° 125° 130°
0.09
0.09
0.10
0.10
0.11
0.17
0.18
0.19
0.20
0.21
0.26
0.27
0.29
0.30
0.32
0.34
0.36
0.38
0.40
0.42
0.43
0.45
0.48
0.50
0.53
0.51
0.54
0.57
0.60
0.63
Unit = Feet
Max Length = A
Max Elevation = B
A
Indoor unit
LA120HYV1
65.6 feet
6.6 feet
≥20 inches
32.8 feet
32.8 feet
0.22
0.11
0.11
0.12
0.13
0.14
0.22
0.22
0.23
0.26
0.28
0.33
0.32
0.35
0.39
0.42
0.44
0.43
0.46
0.52
0.56
0.55
0.54
0.58
0.65
0.70
0.66
0.65
0.69
0.78
0.84
Outdoor unit
B
0.15
0.15
0.29
0.30
0.44
0.45
0.58
0.60
0.73
0.75
0.87
0.90

Advertisement

Table of Contents
loading