Diagnostic Error Code
011-197-XXX
Serial port test warning
011-198-XXX
Serial port test aborted
011-199-XXX
Serial port test failed, cause unknown
011-2XX-XXX
Serial port signal failure
014-000-XXX
Parallel port Interface Test Passed
014-001-XXX
Parallel port Presence
014-002-XXX
014-003-XXX
Parallel port Timeout/Parity error
014-013-XXX
014-014-XXX
Parallel port Control Signal/Loopback test
failure
014-015-XXX
Parallel port External Loopback failure
014-027-XXX
Parallel port Configuration/Setup error
014-03X-XXX
014-04X-XXX
Parallel port failure
014-195-XXX
Parallel port Test aborted by user
FRU/Action
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 51
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 51
2. Flash the system and re-test. See "Flash
update procedures" on page 207
3. Go to "Undetermined problems" on page
81
1. Go to "Undetermined problems" on page
81
2. Flash the system and re-test. See "Flash
update procedures" on page 207
3. Replace component under function test
1. External serial device
2. System board
No action
1. Remove external parallel device, if
present
2. Run setup, enable port
3. System board
System board
System board
1. Wrap plug
2. System board
1. Run Setup, enable port
2. Flash the system. See "Flash update
procedures" on page 207
3. System board
System board
Information only
Re-start the test, if necessary
Chapter 7. Symptom-to-FRU Index
63