Registry
Start > Settings > System > Registry
Choose an MX9 software reload scheme.
Tab
When clicked, a standard load file dialog is opened, to allow the user to pick a Registry Save (.RSG) file. The
Load User
applet then copies the specified User registry file to the Active registry. The user is asked to verify a reboot, and
Defaults
then the applet does a warmboot to activate the new registry.
Load User Defaults takes 20 seconds from SD card, or 10 seconds from internal flash.
Save
When clicked, a standard Save File dialog is opened, to allow the user to name the Registry Save (.RSG) file.
User
The applet then copies the Active registry to the specified User registry file.
Defaults
Save User Defaults takes 30 seconds to save to SD card, or 10 seconds to save to internal flash.
The applet copies the Factory Default registry from the OS to the Active registry (by deleting the current registry).
Load
The user is asked to verify a reboot, and then the applet does a restart to activate the factory default registry. If a
Factory
user password has been set, the applet warns the user that the password will be erased, and asks them to enter
Defaults
it before the reboot is allowed.
Warmboot When clicked, the OS does a registry flush (Active registry saved to Flash registry hive), and then a warmboot.
Restart
When clicked, the OS does a registry flush, and then a restart.
4-112