  • Page 2: Table Of Contents

    4. Set up and use only on a flat, level, work gloves, and dust mask/respirator during set up. well‑ventilated surface. 8. Use only lubricants and fuel recommended in this manual. For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 2 For Engine technical questions, please call 1-800-520-0882.
  • Page 3: Operating Precautions

    6. Keep all spectators at least six feet any non‑insulated conductive object. from the Engine during operation. For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 3 For Engine technical questions, please call 1-800-520-0882.
  • Page 4 These events could ignite fumes or vapors. For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 4 For Engine technical questions, please call 1-800-520-0882.
  • Page 5: Service Precautions

    If unreadable or missing, contact Harbor Freight Tools for a replacement. SAVE THESE INSTRUCTIONS. For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 5 For Engine technical questions, please call 1-800-520-0882.
  • Page 6: Specifications

    Item 69672 ‑ The emission control system for this Generator’s Engine is warranted for standards set by the U.S. Environmental Protection Agency. For warranty information, refer to the last pages of this manual.
  • Page 7 Receptacle (120 volt or 240 volt) that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used. For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 7 For Engine technical questions, please call 1-800-520-0882.
  • Page 8: Operation

    3. Clean the top of the Dipstick and the area around it. Remove the Dipstick by threading it counterclockwise, and wipe it off with a clean lint free rag. For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 8 For Engine technical questions, please call 1-800-520-0882.
  • Page 9: Using The Generator

    Note: Do not allow generator to run subsequent maintenance follows the schedule out of fuel with loads attached. explained in the SERVICE section. For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 9 For Engine technical questions, please call 1-800-520-0882.
  • Page 10: Starting The Engine

    IMPORTANT: Allow the engine to run at no load for five minutes with no load after each start‑up so that the engine can stabilize. For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 10 For Engine technical questions, please call 1-800-520-0882.
  • Page 11: Connecting Electrical Loads

    2. Adjust the plugs so the loads are shared across outlet circuits. To achieve rated output from the generator, distribute loads over outlets. For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 11 For Engine technical questions, please call 1-800-520-0882.
  • Page 12 Furnace Fan ‑ 1/2 HP 1400 there are no additional start‑up watts. Space Heater 1800 Window AC ‑ 10,000 BTU 1200 For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 12 For Engine technical questions, please call 1-800-520-0882.
  • Page 13: Stopping The Engine Under Normal Conditions

    1. Before turning off the Engine, turn off all electrical loads, then unplug them. 2. Turn the Engine Switch off. 3. Close the Fuel Valve. For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 13 For Engine technical questions, please call 1-800-520-0882.
  • Page 14: Maintenance

    Replace fuel line if necessary Service more frequently when used in dusty areas. These items should be serviced by a qualified technician. For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 14 For Engine technical questions, please call 1-800-520-0882.
  • Page 15: Checking And Filling Fuel

    Rinse. Squeeze out excess water and allow it to dry completely. Soak the filter in lightweight oil briefly, then squeeze out the excess oil. For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 15 For Engine technical questions, please call 1-800-520-0882.
  • Page 16: Spark Plug Maintenance

    Open the fuel valve. After all fuel has drained, reinstall the drain bolt and sediment cup (if equipped). Tighten securely. For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 16 For Engine technical questions, please call 1-800-520-0882.
  • Page 17: Troubleshooting

    4. Have qualified technician diagnose/ mis‑adjusted or stuck. repair ignition system. Follow all safety precautions whenever diagnosing or servicing the equipment or engine. For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 17 For Engine technical questions, please call 1-800-520-0882.
  • Page 18 Follow all safety precautions whenever diagnosing or servicing the equipment or engine. For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 18 For Engine technical questions, please call 1-800-520-0882.
  • Page 19: Parts List And Diagram

    Arm, Governor Weight,Balancer Bolt, Governor Arm Camshaft Assy Nut, Flange M6 Ball Bearing 6202 Cover, Dust Ball Bearing 6207 Bolt, Flange M5×10 For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 19 For Engine technical questions, please call 1-800-520-0882.
  • Page 20 Note: If product has no serial number, record month and year of purchase instead. Note: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 20 For Engine technical questions, please call 1-800-520-0882.
  • Page 21: Assembly Diagram

    Assembly Diagram For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 21 For Engine technical questions, please call 1-800-520-0882.
  • Page 22 Assembly Diagram (cont.) Note: Parts 114‑117 and 141‑143 are only on Item 69674 (EPA/CARB version) For Generator technical questions, please call 1-888-866-5797. Item 69672 69674 Page 22 For Engine technical questions, please call 1-800-520-0882.
  • Page 23: Warranty

    Where a warrantable condition exists, HFT will repair your engine at no cost to you including diagnosis, parts and labor. For Item 69672 (EPA version) United States Emission Control Defects Warranty Statement The United States Environmental Protection Agency (herein EPA) and Harbor Freight Tools (herein HFT) are pleased to explain the emission control system warranty on your 2014‑2015 Small Off‑Road Engine (herein engine).
  • Page 24 If you have any questions regarding your warranty rights and responsibilities, you should contact the Harbor Freight Tools Customer Service Department at 1‑888‑866‑5797. Harbor Freight Tools Emission Control Defects Warranty Provisions Length of Coverage HFT warrants to a first retail purchaser and each subsequent purchaser that the engine is free from defects in materials and workmanship that cause the failure of warranted parts for a period of two (2) years after the date of delivery to the first retail purchaser.