Insert the ASP Diagnostics diskette
into the FDD, type A:TESTCE64,
Connect wraparound connectors.
Execute the Running Test
If the Diagnostic Program does not detect any errors, the problem may be an intermittent one.
Execute the running test program several times to isolate the problem.
After confirming which diagnostic test detected an error by checking the Log Utilities function,
perform the appropriate troubleshooting procedures as follows.
1.
If an error is detected on the system test, memory test, display test, ASYNC test, printer
test, real timer test, or expansion test, perform the system board troubleshooting procedures
in Section 2.4.
2.
If an error is detected on the keyboard test, perform the keyboard troubleshooting proce-
dures in Section 2.7.
3.
If an error is detected on the floppy disk test, perform the floppy disk drive troubleshooting
procedures in Section 2.5.
4.
If an error is detected on the hard disk test, perform the hard disk drive troubleshooting
procedures in Section 2.6.
1
and press ENTER.
Do typed
characters appear
correctly?
YES
several times.
Is an error
detected by the
Running Test
?
NO
System is normal.
END
Figure 2-1 Troubleshooting flowchart (continued)
Perform Keyboard
NO
Troubleshooting Procedures in
Section 2.7.
After confirming which test has
YES
detected an error, perform the
appropriate troubleshooting proce-
dures.
2-7