Toshiba RAS-24NKHD-E4 Service Manual page 6

Split wall type
Table of Contents

Advertisement

Note : 1
• Capacity is based on the following temperature conditions.
Temperature
Indoor unit inlet air temperature
Outdoor unit inlet air temperature
Note : 2
• Charge refrigerant according to the table below.
Refrigerant
1
No need to charge
extra refrigerant
2
Need to charge
extra refrigerant
Condition
(DB)
(WB)
(DB)
(WB)
RAS-24NKHD-E4 / RAS-24UAH-E4
RAS-24NKD-E4 / RAS-24UA-E4
RAS-24NKDX4 / RAS-24UAX4
RAS-24NKD-AR4 / RAS-24UA-AR4
RAS-24NKDX4-T / RAS-24UAX3-T1
15 m or less
Over 15 m up to 25 m (30 g/m)
– 5 –
FILE NO. SVM-05016
JIS B8615-1
Cooling
27°C
19°C
35°C
24°C
RAS-18NKHD-E4 / RAS-18UAH-E4
RAS-18NKD-E4 / RAS-18UA-E4
RAS-18NKDX4 / RAS-18UAX4
RAS-18NKD-AR4 / RAS-18UA-AR4
RAS-18NKDX4-T2 / RAS-18UAX4-T2
15 m or less
Over 15 m up to 20 m (20 g/m)
Heating
20°C
15°C
7°C
6°C