2-3 HEAT operation
SWING
TIMER OFF TIMER
CLOCK AUTO AUTO
FAN
CHECK SET TEMP.
START STOP
FILTER
SPEED
AUTO
CHECK MODE
RETURN
TEST RUN
<HEAT operation time chart>
Operation starts by
P O W E R b u t t o n
ON.
ON
Thermostat
OFF
ON
Indoor fan
OFF
ON
Auto vane
OFF
ON
Booster heater
OFF
ON
Compressor
OFF
ON
Power ON lamp
OFF
ON
STAND BY lamp
OFF
w2 Even if the room temperature falls below the set temperature during this period, the compressor will not start until this peri-
od has ended.
Room temperature
becomes equal to
set temperature.
LOW w1
LOW w1
LOW or HIGH
Depends on remote
controller setting
Horizontal
Horizontal
Hot adjustment
Minimum 3 minutes w2
From POWER ON until
warm air begins to blow
<How to operate>
1 Press POWER ON/OFF button.
2 Press the MODE button to display "HEAT"
3 Press the SET TEMP. button to set the desired temperature.
NOTE: The set temperature changes 2°F when the SET TEMP.
button is pressed one time.
Heating 63 to 83°F.
<Display in HEAT operation>
[DEFROST]
The [DEFROST] symbol is only displayed during the defrost opera-
tion.
[STANDBY]
The [STANDBY] symbol is only displayed from the time the heating
operation starts until the heated air begins to blow.
Room temperature
Operation stops by
falls below set tem-
P O W E R b u t t o n
perature.
OFF.
LOW or HIGH
Depends on remote
controller setting
Hot adjustment
34
w1 Changeable LOW or HIGH
by indoor dip switch SW1- 6 .
OFF during thermostat OFF
hot adjustment
defrosting