Installation Guide

Advertisement

Table of Contents
loading

Summary of Contents for Faber SERENE C11

  • Page 1 SERENE C11 EMOTION C11 INTENSE C11 Installation Guide...
  • Page 2 Serene < < < <...
  • Page 3 Emotion / Intense > > > >...
  • Page 4: Table Of Contents

    Content Introduction ..................4 Safety and general information ..............5 Installation requirements ................. 6 False chimney breast ................ 6 Flue requirements................6 Flue restrictor ................7 Terminal position ................7 Using an existing chimney..............7 Instruction for Installation ................ 9 Gas Connection ................
  • Page 5: Introduction

    1 Introduction Note: these instructions should be read carefully and retained for future reference. Please leave these instructions with the user. Special features: • The Serene can be build on all desired heights • Room sealed appliance, inlet and outlet are led to the outside using a natural draught concentric pipe system (100 mm/150 mm) (no power fan required) •...
  • Page 6: Safety And General Information

    2 Safety and general information Before installation, ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible. This gas appliance is factory set and can not be adjusted. This appliance does not contain any component manufactured from asbestos or any asbestos related products.
  • Page 7: Installation Requirements

    The appliance is of the type C11/C31. The appliance will need to be supplied with the approved Faber flue pipes and terminal, it is not possible to supply your own. The minimum effective height of the flue system must be 1 meter.
  • Page 8: Flue Restrictor

    1. each 90-degree bend, which is in the horizontal area, counts for 2 meter 2. each 45-degree bend, which is in the horizontal area, counts for 1 meter 3. elbows and bends at the transition from horizontal to vertically are not to be counted 4.
  • Page 9 • A chimney that has previously been used for solid fuel must be swept before use. • The existing chimney needs to be airtight. • The existing chimney needs to have an opening of min. 150 x 150 mm. • The chimney needs to be intact and well looked after.
  • Page 10: Instruction For Installation

    4 Instruction for Installation Gas Connection • Installation pipes should be in accordance with BS 6891. Pipe work from the meter to the appliance must be of adequate size. • The complete installation including the meter must be tested for soundness and purged as described in the above code.
  • Page 11: Building The Serene In A False Chimney Breast

    those prints once they are burned in the glass: o Place the glass in front of the appliance and fix it with the glass clamps. Replace the frame. o Check on visual leakages around the door sealing. Building the Serene in a False Chimney Breast •...
  • Page 12: Placing The Log Set

    Never place extra elements of any kind into the combustion chamber. To guarantee good combustion, the log set may only be installed in the way specified by Faber International. Any other arrangement can lead to soot on logs or window. Do not use the fire with broken or missing logs.
  • Page 13: Commissioning (Functional Checks)

    5 Commissioning (functional checks) Pilot ignition check • Ignite the pilot light as described in the user manual • Check if the pilot burner stays alight • Extinguish the pilot burner Check functional burner and pilot burner The appliance is preset to give the correct heat input. No further adjustment is necessary. Always check the inlet pressure and burner pressure: •...
  • Page 14: Handing Over (Final Check And Customer Briefing)

    6 Handing over (final check and customer briefing) Instruct the customer on the full operation of the appliance and the remote control, including replacement of batteries Advise the customer how to clean the appliance including the glass Hand over these instructions including the user guide to the consumer Recommend that the appliance should be serviced by a competent person at least once a year 7 Servicing...
  • Page 15: Converting To Butane/Propane

    Converting to butane/propane Rebuilding to another gas category is only possible by exchanging the complete burner plate. Ask your local dealer and bring the serial number of the appliance. Pilot assembly Burner Fixation plate Injector Gas control Receiver > > >...
  • Page 16: Appendix A: Example Calculation

    Appendix A: Example calculation Calculation 1: Calculating horizontal extension fig. 2a: Flue length C + E = 1m + 1m Elbows D = 2m Total horizontal extension Measure or calculate effective height (Hvert) Flue length A Roof mounted terminal Total effective height Always check if the calculated situation is allowed (see appendix B: Flue restrictor) Calculation 2:...
  • Page 17: Appendix B: Flue Restrictor

    Appendix B: Flue restrictor Determine the right flue restrictor: • Calculate the total horizontal- and vertical length of the flue, according to the calculations in Appendix A • Determine according to the table the right flue restrictor size • When meeting an X, and when the values are outside the table, the combination is not allowed •...
  • Page 18: Appendix C: Technical Specifications Serene

    Appendix C: Technical specifications Serene Logburner Logburner Logburner Country UK / IRL UK / IRL UK / IRL II 2E+3+ II 2H3+ II 2H3+ Appliance type C11 / C31 C11 / C31 C11 / C31 Reference gas Input (Nett) Efficiency class Inlet pressure mbar Gas rate*...
  • Page 19: Appendix D: Dimensions Serene

    Appendix D: Dimensions Serene > > > >...
  • Page 20: Appendix E: Dimensions Emotion

    Appendix E: Dimensions Emotion 19 < < < <...
  • Page 21: Appendix F: Dimensions Intense

    Appendix F: Dimensions Intense > > > >...
  • Page 22: Appendix G: Dimensions Convection Grid

    Appendix G: Dimensions Convection grid 21 < < < <...
  • Page 23 > > > >...
  • Page 24 – info@faber.nl Saturnus 8 NL - 8448 CC Heerenveen Postbus 219 NL - 8440 AE Heerenveen T. +31(0)513 656500 F. +31(0)513 656501...

Table of Contents