Page 1
USER GUIDE BUSINESS SERIES 24-Port or 48-Port 10/100 + 4-Port 10/100/1000 Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs SLM224G4S, SLM248G4S Model:...
Chapter 1 Chapter 1: Introduction Thank you for choosing the Linksys 24/48-Port 10/100 + 4-Port Gigabit Smart Switch with Resilient Clustering Technology and 2 Combo SFPs. These switches allow you to expand your network securely. Configuration of the switch is secured using SSL for Web access.
(10 Mbps, 100 Mbps, or 1000 Mbps), and adjust its speed and duplex accordingly. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs miniGBIC (1-2) converter) port is a connection point for a miniGBIC expansion module, so the Switch can be uplinked via fiber to another switch.
A hub refers to any type of 100 Mbps hub. A 10 Mbps hub connected † to another 10 Mbps hub can span up to 100 meters (328 feet). 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Pre-Installation Considerations Fast Ethernet Considerations...
(e.g. use of power strips). 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs To rack-mount the Switch in any standard 19-inch wide, 1U-high rack, follow the instructions described below.
Smart Switches are connected together to effectively form a single switch. The default operating mode is stacking mode. A Switch stack can contain any combination of SLM224G4S and SLM248G4S units, with the following limits: SLM224G4S only: Maximum of 6 units •...
Connect the cable’s other end to port G2 on Unit 1. For a stack with less than 6 switches, the steps are similar except that port G1 of the last switch in the stack must be connected back to port G2 of the first switch in the stack.
Select a port to communicate with the switch. Select COM1 or COM2. HyperTerminal Connect To Screen 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Set the serial port settings as follows, then click OK. Bits per Second: 8400...
Use the arrow keys to select Execute and press Enter to complete the login process. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Switch Main Menu After successful login, the Main Menu screen appears. This...
Page 16
Description, System Up Time, System MAC Address, System Contact, System Name and System Location. General System Information 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Management Settings The Management Settings screen displays the Serial Port Configuration option.
Page 17
NOTE: This setting has no effect when Management Access Rules are not defined. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs IP Configuration The IP Configuration screen displays three menu choices: IP Address Settings, HTTP Configuration, and Network Configuration.
Page 18
The TraceRoute screen displays the IP address of the address whose route you want to trace. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs TraceRoute Select Edit to change the IP address, and select Execute to begin the traceroute test.
Page 19
DEVICE! Download the new software image. Reset the device now. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Restore System Default Settings To restore the Switch back to the factory default settings, select Restore System Default Setting and press Enter.
You can enable or disable a port, or set its auto-negotiation status, speed and duplex mode, and flow control status. Port Configuration 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs System Mode The System Mode screen displays information about the system mode:...
“Admin > User Authentication. ” ) Login Screen 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Each time you log in, the web-based utility first displays the Setup tab’s Summary screen.
Displays the current time. This setting can be configured from the Setup tab’s Time screen. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Click Save Settings to save your changes. Click Cancel Changes to cancel your changes.
Click Save Settings to save your changes. Click Cancel Changes to cancel your changes. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Setup > Time The Time screen allows you to configure the time settings for the Switch.
Force Master, then select unit 1 or 2 from the drop-down menu. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility NOTE:...
Page 25
Port Management > Port Settings> Port Configuration The Port Configuration screen contains the following fields (“Read-only” indicates that a field cannot be edited). 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Port The port number.
Click Save & Close to save the settings and close the screen. Click Close to close the screen without saving the settings. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Port Management > Link Aggregation speed Port Management >...
Select Enable or Disable to manually enable or disable flow control, or select Auto- Negotiation for automatic selection of flow control. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Current Flow Control (Read-only) The current flow control setting.
The Create VLAN screen lets you create and configure global parameters for VLANs. VLAN Management > Create VLAN 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Single VLAN To create a single VLAN, enter the VLAN ID and VLAN Name, up to 32 characters long, and click Add.
Select the unit that contains the ports for the VLAN you are configuring. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility For each port in the VLAN, select the appropriate...
Statistics > RMON Statistics Statistics > RMON Statistics 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility This screen allows you to display RMON statistics for the Ethernet port or LAG that you specify.
Click Add to List to add the configured RMON sampling to the Log Table at the bottom of the screen. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Log Table Source Interface history samples were taken.
Network alarms occur when a network problem, or event, is detected. Rising and falling thresholds generate events. Statistics > RMON Alarm 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Add Alarm Alarm Entry Indicates a specific alarm.
Click Add to List to add the configured RMON event to the Event Table at the bottom of the screen. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Event Table The Event Table lists all events defined using the Add Event fields.
Internal MAC Receive Errors Displays the number of internal MAC received errors on the selected interface. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Received Pause Frames paused frames on the selected interface.
EAP requests are resent to the supplicant. The range is 1 to seconds. The default is 0 seconds. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Server Timeout before the switch resends a request to the authentication server The range is 1 to .
Page 36
Switch. Click Save Settings to apply the changes, or Cancel Changes to cancel the changes. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Security > Management Access List...
The Update button adds the Storm Control settings to the Storm Control table at the bottom of the screen. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Security > RADIUS...
The QoS configuration options are CoS Settings, Queue Settings, DSCP Settings, and Basic Mode. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility QoS > CoS Settings The CoS Settings screen is used to enable or disable CoS.
Changes to cancel the changes. QoS > DSCP Settings QoS > DSCP Settings 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility The DSCP Settings screen allows you to map Differentiated Services Code Point (DSCP) values to specific queues.
Loops in an extended network can cause bridges to forward traffic indefinitely, resulting in increased traffic and reducing network efficiency. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility The Switch supports the Classic STP version of STP, which...
The default path costs assigned to an interface varies according to the selected method. This is the default value. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Bridge Settings Priority Specifies the bridge priority value.
Click Update to update the screen with your changes. Click Save Settings to save the changes, or Cancel Changes to cancel the changes. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Multicast Multicast configuration options include IGMP Snooping, Bridge Multicast, and Bridge Multicast Forward All.
Multicast service groups to be created. The Bridge Multicast screen also assigns ports to a specific Multicast service address group. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility The Bridge Multicast screen contains the following fields:...
Communities, Notification Filter, and Notification Recipient. SNMP > Global Parameters SNMP > Global Parameters 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility The Global Parameters screen contains parameters for defining SNMP notification parameters.
Defines the security level attached to the group. Security levels apply to SNMPv3 only. The possible field values are: 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility No Authentication Indicates that neither the •...
The Communities screen is used to define SNMP communities. The Communities screen contains the following three areas: Communities, Basic Table and Advanced Table. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility SNMP > Communities SNMP Management Station...
Object ID Enter an OID not offered in the Select from • List option. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Filter Type Indicates whether informs or traps are sent regarding the OID to the trap recipients.
It includes the following screens: Admin > User Authentication Admin > User Authentication 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility The User Authentication screen is used to modify user account information.
MAC Address This is the physical address that is being mapped to the specified interface. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility VLAN ID The VLAN ID number (1-4094) of the configured VLAN that is associated with the specified interface.
Source Port The port whose traffic will be monitored. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Type Allows you to select which traffic to mirror to the target port;...
Press this button to begin the cable test. • Admin > Cable Test - Gigabit Ports > Copper Cable Extended Feature 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Admin > Save Configuration Admin >...
• click Browse to locate the upgrade file. Click Save Settings to begin the download or upload. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Admin > Reboot The Reboot screen is used to reset one Switch or the entire stack.
Provides detailed information about the log. If • a Debug error occurs, contact Customer Tech Support. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility If you enable Logging, use the checkboxes to set the level of event messages to be logged to RAM (Memory Logs) and flash memory (Flash Logs), then click Save Settings.
Severity Displays the log severity. Description Displays the log message text. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Configuration Using the Web-based Utility Logout The Logout tab is used to terminate the login session.
In Europe, the round ST connector is more prevalent. For Gigabit Ethernet, you must use the Linksys MGBT1, MGBSX1, or MGBLH1 miniGBIC modules with the Linksys Gigabit Switches. The MGBSX1 and the MGBLH1 require fiber cabling with LC connectors, and the MGBT1 requires a Category 5e Ethernet cable with an RJ-45 connector.
Stack. A Stack consists of one Master control switch, a Master Backup switch, and up to four Stack Member SLM224G4S switches, or up to two Stack Member SLM248G4S switches. As a special case, a unit in Stack mode not connected •...
24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs About Switch Stacking Units that are assigned Unit IDs 3-6 (SLM224G4S) or • Unit IDs 3-4 (SLM248G4S) are called Stack Members. A stack member will only operate as a member of...
Unit ID is either 1 or 2, then one of these two units will be the stack Master. It does not matter if the Unit 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs About Switch Stacking ID was originally assigned automatically or manually.
If any change is made to the system configuration, the change will be stored by 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs About Switch Stacking the stack Master and will be copied to the Backup Master (if it exists).
Unit ID, it will be configured as the original failed 48- port unit was configured). 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs About Switch Stacking If a 48-port unit replaces a 24-port unit, then •...
“Replacing a Failed Stack Member in a Running Stack” above. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs About Switch Stacking Since this subgroup contains both master and backup, •...
In this example one should distinguish between two scenarios: 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs About Switch Stacking The incoming units are turned off before insertion and •...
Master. The total of existing units and inserted units would exceed the maximum allowed number of units in a stack, which is 6 units for SLM224G4S, or 4 units for SLM248G4S: Master Detection and Master Election processes •...
Bandwidth Assignments Indicates the amount of bandwidth assigned to a specific application, user, and/or interface. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Baud Indicates the number of signaling elements transmitted each second. Best Effort Indicates that traffic is assigned to the lowest priority queue, and packet delivery is not guaranteed.
Page 65
FTP (File Transfer Protocol) A protocol used to transfer files over a TCP/IP network. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Full Duplex The ability of a networking device to receive and transmit data simultaneously.
Page 66
(rules). QoS allows network managers to decide how and what network traffic is forwarded according to priorities, application types, and source and destination addresses. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs RADIUS (Remote Authentication Service) A protocol that uses an authentication server to control network access.
Page 67
For example, if the destination IP address is 149.36.184.198 and the wildcard mask is 255.36.184.00, the first two bits of the IP address are used, while the last two bits are ignored. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs...
The internet URL address and the web pages referred to herein may be updated by Linksys from time to time; the version in effect at the date of purchase shall apply. This limited warranty is non-transferable and extends only to the original end-user purchaser.
Appendix E Warranty Information product to Linksys at your cost and risk. You must include the RMA number and a copy of your dated proof of original purchase when returning your product. Products received without a RMA number and dated proof of original purchase will be rejected.
State of California to cause cancer, and birth defects or other reproductive harm. Wash hands after handling. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Regulatory Information Industry Canada Statement This Class A digital apparatus complies with Canadian ICES-003.
(WEEE) This document contains important information for users with regards to the proper disposal and recycling of Linksys products. Consumers are required to comply with this notice for all electronic products bearing the following symbol: English - Environmental Information for Customers in...
Page 74
παλιού σας εξοπλισμού, παρακαλώ επικοινωνήστε με τις τοπικές αρχές, τις υπηρεσίες απόρριψης ή το κατάστημα από το οποίο αγοράσατε το προϊόν. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Français (French) - Informations environnementales pour les clients de l’Union européenne La directive européenne 2002/96/CE exige que l’équipement...
Page 75
üzlettel, ahol a terméket vásárolta. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Regulatory Information Nederlands (Dutch) - Milieu-informatie voor klanten...
Page 76
24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Regulatory Information Slovenčina (Slovene) - Okoljske informacije za stranke...
Support 800-326-7114 RMA (Return Merchandise http://www.linksys.com/warranty Authorization) NOTE: Details on warranty and RMA issues can be found in the Warranty section of this Guide. 24/48-Port 10/100 + 4-Port Gigabit Resilient Clustering Smart Switch with 2 Combo SFPs Contact Information 8012510A-AI...