free hit counter
Harman TL300 Owner's Manual Installation And Operation
Harman TL300 Owner's Manual Installation And Operation

Harman TL300 Owner's Manual Installation And Operation

Non-catalytic, top load, wood burning room heater
Hide thumbs Also See for TL300:

Advertisement

Owner's Manual
Installation and Operation
Model:
TL300
Non-Catalytic, Top Load,
Wood Burning Room Heater
Contact your local dealer with questions on installation,
operation or service.
Important operating and
maintenance instructions
included.
!
Please read this entire manual before
installation and use of this wood-burning
room heater.
Failure to follow these instructions could
result in property damage, bodily injury
or even death.
• Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
• Do not overfire - If any external part starts to glow,
you are overfiring. Close air controls. Overfiring will
void your warranty.
• Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause a house
fire.
!
CHECK BUILDING CODES PRIOR TO INSTALLATION.
• INSTALLATION MUST COMPLY WITH LOCAL, REGIONAL,
STATE AND NATIONAL CODES AND REGULATIONS.
• CONSULT LOCAL BUILDING, FIRE OFFICIALS OR
A U T H O R I T I E S H AV I N G J U R I S D I C T I O N A B O U T
RESTRICTIONS, INSTALLATION INSPECTION, AND
PERMITS.
To obtain a French translation of this manual, please contact your dealer or visit www.harmanstoves.com.
Pour obtenir une traduction française de ce manuel, s'il vous plaît contacter votre revendeur ou visitez www.harmanstoves.com.
Save These Instructions
DO NOT DISCARD THIS MANUAL
Read, understand and
follow these instructions
for safe installation and
operation.
WARNING
CAUTION
Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15
NOTICE
Leave this manual with
party responsible for use
and operation.
Hot, will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room
as fireplace.
Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other
flammable materials away.
TESTED AND APPROVED FOR USE WITH DRY,
SEASONED CORDWOOD ONLY. DO NOT BURN WET
OR GREEN WOOD. BURNING ANY OTHER TYPE OF
FUEL WILL VOID YOUR WARRANTY.
Wood Stove
Use & Care Video
!
WARNING
HOT SURFACES!
Glass and other surfaces
are hot during operation
AND cool down.
!
CAUTION
3-90-06901

Advertisement

Table of Contents
loading

Summary of Contents for Harman TL300

  • Page 1 To obtain a French translation of this manual, please contact your dealer or visit www.harmanstoves.com. Pour obtenir une traduction française de ce manuel, s’il vous plaît contacter votre revendeur ou visitez www.harmanstoves.com. Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 3-90-06901...
  • Page 2 Hearth & Home Technologies welcomes you to our tradition of excellence! By choosing a Harman appliance, you have become part of our commitment to meeting the heating needs of consumers with the most distinctive, powerful and responsible home heating products available.
  • Page 3: Table Of Contents

    G. Building and Maintaining a Fire ....25 Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Dry Seasoned Wood Only!
  • Page 4: Appliance Certifications

    Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass if needed. D. Electrical Rating Optional Blower: 115 VAC, 60 Hz. <1 Amps Dry Seasoned Wood Only! Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Save These Instructions...
  • Page 5: Section 2: Special Warning And Notes A. Carbon Monoxide Warnings & Considerations

    CO fumes are toxic and can be fatal. NEVER CONNECT THIS UNIT TO A CHIMNEY FLUE The TL300 is a natural draft system which relies on a properly SERVING ANOTHER APPLIANCE. designed chimney to remove CO and other combustion by- products from the stove.
  • Page 6: Design, Installation & Location

    DO NOT CONNECT TO ANY FORCED AIR DISTRIBUTION DUCT OR SYSTEM. Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies recommends Factory Trained or NFI Certified professionals. Dry Seasoned Wood Only! Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Save These Instructions...
  • Page 7: Component Locator

    Top Load Opening Front Load Door Top Load Grate Door Handle Andirons Air Control Ash Door Front Load Door Latch Ash Door Latch Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Dry Seasoned Wood Only!
  • Page 8: Pre-Use Checklist

    A properly grounded electrical receptacle is OR ANY SUCH ACTION THAT MAY CAUSE A FIRE available within reach of the blower's power HAZARD. cord (if installed). Dry Seasoned Wood Only! Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Save These Instructions...
  • Page 9: Section 4: Dimensions & Clearances

    Dimensions & Clearances A. Appliance Dimensions 29-3/8” 27-1/16” 746 mm 687 mm 29-3/8” 27-1/16” 746 mm 687 mm Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Dry Seasoned Wood Only!
  • Page 10: Clearances To Combustibles

    This unit was not tested for installation into an Alcove. Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel– Burning Appliances". Dry Seasoned Wood Only! Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Save These Instructions...
  • Page 11 This unit was not tested for installation into an Alcove. Follow NFPA 211 Table 13.6.1 "Clearances for Solid Fuel– Burning Appliances". Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Dry Seasoned Wood Only!
  • Page 12: Floor Protection

    The United States. In Canada, the side dimension is measured from the widest part of the appliance. Dry Seasoned Wood Only! Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Save These Instructions...
  • Page 13: Section 5: Chimneys & Venting

    NFPA 211 code. the design and placement of your venting system. The Harman TL300 may be installed with a minimum (.6mm) 24 gauge blue or black steel, chimney connector pipe. The size of the connector should correspond to the size of the flue collar opening, which is 6"...
  • Page 14: The Chimney

    Chimney 3ft. - Above roof exit point THE 3-FOOT, 2-FOOT, 10 FOOT RULE 2ft. - Higher than anything within- 10ft. of the chimney. Dry Seasoned Wood Only! Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Save These Instructions...
  • Page 15 The Chimney and connector must be maintained in good condition and kept clean. Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Dry Seasoned Wood Only!
  • Page 16 Chimney Connector The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a Floor or Ceiling. Dry Seasoned Wood Only! Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Save These Instructions...
  • Page 17 Cathedral Ceiling Installation with Factory Built Chimney Chimney cap Factory-Built metal Sealed storm chimney collar Roof flashing Roof radiation shield Cathedral style chimney support Finishing collar Chimney Connector Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Dry Seasoned Wood Only!
  • Page 18 *Floor protection in accordance with Solid Fuel Appliance Listing The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a Floor or Ceiling. Dry Seasoned Wood Only! Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Save These Instructions...
  • Page 19 ** Check with your local building codes inspector for clearance. The Chimney Connector Shall Not Pass Through an Attic or Roof Space, Closet or Similar Concealed Space, a Floor or Ceiling. Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Dry Seasoned Wood Only!
  • Page 20: Mobile Home Installation

    FLOOR JOIST, WALL STUDS, OR CEILING TRUSSES. (HUD), CFR 3280, PART 24. • ANY SUPPORTING MATERIAL THAT WOULD AFFECT THE STRUCTURAL INTEGRITY. WARNING DO NOT INSTALL IN SLEEPING ROOM. Dry Seasoned Wood Only! Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Save These Instructions...
  • Page 21: Section 7: Appliance Set-Up

    When you burn your next hot fire, the glass will likely clean itself. Keep top load door closed except when loading or Outside Air unloading grill. Attachment Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Dry Seasoned Wood Only!
  • Page 22: Optional Blower Kit

    The optional blower kit installs easily to the rear of the door down flat on it's face. Drill the dimpled holes in each TL300. First, install the Blower Mount to the rear of the corner of the door and re-install the door onto the stove. stove using (4) 1/4-20 x 1/2" bolts as shown below.
  • Page 23: Section 8: Operating Instructions

    FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. DO NOT BURN GARBAGE OR FLAMMABLE LIQUIDS SUCH AS GASOLINE, NAPTHA, OR ENGINE OIL. Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Dry Seasoned Wood Only!
  • Page 24: Burning As A Fireplace

    Always be sure to provide adequate ventilation to the room where the appliance is located, to prevent air starvation. In tight construction, consider installing outside air to the appliance. Dry Seasoned Wood Only! Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Save These Instructions...
  • Page 25: User Controls

    You must have this charcoal bed established before you close the bypass damper. Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Dry Seasoned Wood Only!
  • Page 26 Providing you have the charcoal bed described, close the The TL300 is designed to provide access to the ash pan bypass damper by pulling the handle toward the front of the without the need for opening the main door. Before opening stove. This will begin the highly efficient mode of operation...
  • Page 27: Section 9: Service & Maintenance

    Harman wood stoves. Use of chemical creosote removal products will void the warranty of the Firedome combustion system. Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Dry Seasoned Wood Only!
  • Page 28: General Maintenance Procedures

    WARNING DO NOT ABUSE GLASS BY STRIKING OR SLAMMING THE DOOR CLOSED. THIS TYPE OF BREAKAGE IS NOT COVERED BY THE PRODUCT WARRANTY. Dry Seasoned Wood Only! Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Save These Instructions...
  • Page 29 Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Dry Seasoned Wood Only!
  • Page 30: Section 10: Reference Materials

    1-90-06900-4 (Metallic Blue) (Ending Manufacturing Date: Jan 2010) 1-90-06900-12 (Forest Green) (Ending Manufacturing Date: Jan 2010) Part number list on following page. 06/15 Dry Seasoned Wood Only! Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 Save These Instructions...
  • Page 31 Gasket, Ash door 5 Ft 1-00-10000 Wooden Knob, Ash Door Pkg of 3 3-40-08746-3 Bolt on Ash Door Hinge 2-00-06952B Additional service part numbers appear on following page. Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 3-90-06901...
  • Page 32 Pkg of 100 3-30-3016-100 Hardware Package (Includes Drive Arm Washer, Pusher 18.12 1-00-06901 Block Bushing, Wave Washer, Screws) Additional service part numbers appear on following page. Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 3-90-06901...
  • Page 33 Inlet Brick Right 3-40-00104 19.11 Right Inside Plate Assembly w/Gasket 1-10-249118A 19.12 Shoe Brick Gasket 3-44-06951 19.13 Shoe Brick 3-40-00100 Additional service part numbers appear on following page. Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 3-90-06901...
  • Page 34 Spring Clips (Required for installation of Tile Frame) Pkg of 20 3-31-232547-20 Trim Kit, Brushed Stainless 1-00-06931-7 Pre 008324098 3-42-1990 Touch Up Paint Post 008324098 3-42-19905 Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 3-90-06901...
  • Page 35: Warranty Policy

    Limited 3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645F 02-18-13 Page 1 of 2 Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 3-90-06901...
  • Page 36 This warranty gives you specific rights; you may also have other rights, which vary from state to state. EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645F 02-18-13 Page 2 of 2 Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 3-90-06901...
  • Page 37 Service & Maintenance Log Date Of Service Performed By Description Of Service Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 3-90-06901...
  • Page 38 Printed in U.S.A. Save These Instructions Harman® • TL300 Owner's Manual_R25 • 2007 -___ • 08/15 3-90-06901...

Table of Contents