No. Page
Item
10 TIMECODE
TC OUT
DF/NDF
(when SYSTEM
FREQUENCY is
set to "59.94i")
EXT-LK DF/NDF
(when SYSTEM
FREQUENCY is
set to "59.94i")
EXT-LK UBIT
LTC UBIT
WATCH AUTO
ADJ
UBIT GROUP ID 000/101
11 ESSENCE
RET SHOT
MARK
MARK 1
RET SHOT
MARK 2
INDEX PIC. POS 0SEC to 10SEC
Settings
Description
AUTO/GENE
Selects the timecode signal output.
AUTO: Outputs the timecode generator output
during recording and outputs the timecode
reader output during playback.
GENE: Outputs the timecode generator output
during recording and playback.
DF/NDF
Sets DF or NDF mode.
DF: Drop frame mode
NDF: Non-drop frame mode
INT/EXT
Selects either internal setting or external setting for
DF/NDF.
INT: Internal
EXT: External
INT/EXT
Sets whether the LTC UBIT setup value locks to an
INT or an EXT source when the timecode is locked
to an external source.
INT: Internal lock
EXT: External lock
FIX/TIME
Sets the data to be recorded in UBIT of LTC.
FIX: Records the data that is set by the user.
TIME: Records the present time.
OFF/ON
Matches the time of the internal clock with the time
data of the user bits of an external timecode. Turns
the automatic time correction function of the
internal clock on or off.
Selects the UBIT GROUP ID.
OFF/ON
For details, see "Recording essence marks" on page
75.
OFF/ON
For details, see "Setting the thumbnail image at
(in 1 sec steps)
recording time" on page 75.