Instruction Guide:
Elite Communicating Thermostats
TPCm32U03/TPCm32U04

Thermostat Operation

NOTE: These communicating thermostats communicate via a
4-wire modbus protocol and will only operate with the aurora
Control System. TPCm32U03 is not applicable to variable speed
compressor equipment.
Adjusting Temperature
(Temporary Override in Programmable models)
1.
Before you can adjust the temperature, a mODE must be
selected. If you are already in a heating or Cooling mode,
then skip to step 5.
2.
To select a mODE, use the keypad
arrows to scroll to mODE, and then
press the center button on the key
pad to enter the operating mode
menu.
3.
Select the desired mode by
scrolling up or down, with the
arrows, and then press the center
button on the keypad to enter into that mode.
4.
You are now returned to the main menu and Figure 1 is a
similar view. NOTE: Outdoor temperature is only displayed
if an outdoor sensor is installed.
5.
To increase the temperature set point, use the arrow up
button. To decrease the set point, use the arrow down
button. Press the center button on the key pad for the new
set point to be effective
Setting Date And Time
1.
From the main menu, scroll to mENU and press the center
button ■ on the keypad.
2.
Select SET DaTE aND TImE
3.
If your area observes daylight savings time, select aUTO
DaYlIGhT SaVING, scroll to ON, then press the center
button ■ to save. You will be returned to the select SET
DaTE aND TImE menu. Scroll to SET DaTE aND TImE
and press the center button ■ on the keypad.
4.
SET MONTH by using the up and down arrows ▲▼, and then
press the center button on the keypad to save the month.
5.
SET DAY by using the up and down arrows ▲▼, and then
press the center button on the keypad to save the day.
6.
SET YEAR by using the up and down arrows ▲▼, and then
press the center button on the keypad to save the year.
7.
SET HOUR by using the up and down arrows ▲▼, and then
press the center button on the keypad to save the hour.
8.
SET MINUTE by using the up and down arrows ▲▼, and
then press the center button ■ on the keypad to save the
minute.
9.
Date and Time are now set. You can return to the main
menu by pressing the left arrow key to return to the
previous menu.
Hold Setting
Vacation and Permanent (Programmable models only)
This section describes the hOlD functions. You can program
the thermostat to hold the temperature for a period of time.
IG1602EW
06/12
INSTRUCTION GUIDE: ElITE COmmUNICaTING ThERmOSTaT
Figure 1
If you want to hold the temperature for a few hours or a few
weeks, your thermostat can accommodate your schedule.
Vacation Hold
(Programmable models only)
1.
From the main menu, scroll to mENU and press the center
button ■ on the keypad.
2.
Select HOLD → VACATION
3.
First, the thermostat prompts you for a temperature to hold.
If you are in aUTO mODE you will be prompted for both
a heat setting and a cool setting. Use the up and down
arrows keys ▲▼ to select the desired temperature and
press the center button on the keypad.
4.
Next it will prompt you for a date and time that you wish
to return to programmed operation. Returning to the main
Screen, you will notice that in the upper part of the screen
is alternating hOlD TIl *date and time you specified* and
the actual date and time.
5.
To cancel this hold, scroll to CaNCEl hOlD from the main
Menu and press the center button ■.
Permanent Hold
(Programmable models only)
1.
From the main menu, scroll to mENU and press the center
button ■ on the keypad.
2.
Select HOLD → PERMANENT
3.
First, the thermostat prompts you for a temperature to hold.
If you are in aUTO mODE you will be prompted for both
a heat setting and a cool setting. Use the up and down
arrows keys ▲▼ to select the desired temperature and
press the center button on the keypad.
4.
Returning to the main Screen, you will notice that in the
upper part of the screen is alternating PERmaNENT hOlD
and the actual date and time.
5.
You can adjust to permanent hold temperature at will, and
the temperature you select will remain until the permanent
hold is canceled.
6.
To cancel this hold, scroll to CaNCEl hOlD from the main
Menu and press the center button ■. This will revert to the
programmed settings.
1
Elite Communicating Thermostats
TPCM32U03/TPCM32U04

Advertisement

Table of Contents
loading

Summary of Contents for WaterFurnace TPCM32U03

  • Page 1: Thermostat Operation

    TPCm32U03/TPCm32U04 Thermostat Operation NOTE: These communicating thermostats communicate via a 4-wire modbus protocol and will only operate with the aurora Control System. TPCm32U03 is not applicable to variable speed compressor equipment. Adjusting Temperature (Temporary Override in Programmable models) Before you can adjust the temperature, a mODE must be selected.
  • Page 2: Programmed Fan

    INSTRUCTION GUIDE: ElITE COmmUNICaTING ThERmOSTaT Fan Operation button ■ on the keypad. Select SETINGS → SCREEN SETTINGS →BACKLIGHT The thermostat can operate the fan in four ways: ON TImE aUTO (on only during heating and cooling calls) You can change the backlight on time by using the up and ON (always on) down arrows ▲▼.
  • Page 3: Advanced Settings

    INSTRUCTION GUIDE: ElITE COmmUNICaTING ThERmOSTaT Advanced Settings MENU → SETTINGS → AUTO CHANGEOVER Security Lockout Auto Changeover Time – This setting sets the minimum off time This thermostat has the option to set before the thermostat can change from one mode to security features to lockout everything but another.
  • Page 4: Installer Information/Advanced Features

    INSTRUCTION GUIDE: ElITE COmmUNICaTING ThERmOSTaT Installer Information/Advanced Features MENU → SETTINGS → INTERmITTENT FaN Safety Considerations If the FaN hasn’t been on for an hour, Improper wiring or installation may damage thermostat. Wiring the fan will start cycling based on these must conform to local and national electrical codes times.
  • Page 5: Installer Settings

    INSTRUCTION GUIDE: ElITE COmmUNICaTING ThERmOSTaT Installer Settings Connect wires to proper terminal of the connector block in the front plastic. NOTE: These options are intended to be used by the installer. Push any excess wire back into wall. Excess wire inside the End users are not advised to change or modify any of these thermostat plastic case can interfere with proper air flow settings.
  • Page 6 INSTRUCTION GUIDE: ElITE COmmUNICaTING ThERmOSTaT To cancel the message, select the CaNCEl alaRm, and press Both – hUmIDIFY operates in the hEaT mode and the center button ■. DEhUmIDIFY operates in COOl mode. None – Neither is active. Input Dealer Info Reversing Valve Option Contractors are able to input Contractor Name, and Contractor Phone number into these screens.
  • Page 7: Cooling Lockout

    INSTRUCTION GUIDE: ElITE COmmUNICaTING ThERmOSTaT Faults Events Per Day This is where you can set the number of events per day. (an Non-Critical Faults event is a period of time scheduled with a certain heating and Non-critical faults are displayed 
...
  • Page 8 INSTRUCTION GUIDE: ElITE COmmUNICaTING ThERmOSTaT NOTES ©2012 WaterFurnace International, Inc., 9000 Conservation Way, Fort Wayne, IN 46809-9794. WaterFurnace has a policy of continual product research and development and reserves the right to change design and specifications without notice. IG1602EW 06/12...

This manual is also suitable for:

Tpcm32u04

Table of Contents