Toshiba RAV-SM562XT-E Installation Manual
Hide thumbs Also See for RAV-SM562XT-E:

Advertisement

AIR CONDITIONER (SPLIT TYPE)
CLIMATISEUR (TYPE SPLIT)
KLIMAGERÄT (SPLIT-SYSTEM)
CONDIZIONATORE D'ARIA (TIPO SCOMPONIBILE)
APARATO DE AIRE ACONDICIONADO (TIPO SPLIT)
AR CONDICIONADO (TIPO SPLIT)
AIRCONDITIONER (GESPLITST TYPE)
ΚΛΙΜΑΤΙΣΤΙΚΟ ΜΗΧΑΝΗΜΑ (∆ΙΑΙΡΟΎΜΕΝΟΣ ΤΎΠΟΣ)
<Under Ceiling/Console Type>/<Type Sous Plafond/Console>
<Unterdecken-/Konsolenmodell>/<Tipo a Soffitto/Console>
<Tipo Instalación en Techo/Consola>/<Sob Tecto/tipo de Consola>
<Plafond-/Consoletype>/<Τυποσ Για Τοποθετηση Κατω Απο Την Οροφη/Kονσολασ>
Heat Pump Model/Modèle à thermopompe
Geräte mit Heizung/Modello con pompa di riscaldamento
Modelo con bomba de calor/Modelo de bomba térmica
Model met warmtepomp/Μοντέλο µε Αντλία Θερµ τητας
Indoor Unit/Unité intérieure
Raumeinheit/Unità interna
Unidad interior/Unidade interior
Binnenunit/Εσωτερική Μονάδα
RAV-SM562XT-E
RAV-SM802XT-E
Please read this Installation Manual carefully before installing the Air Conditioner.
• This Manual describes the installation method of the indoor unit.
• For installation of the outdoor unit, follow the Installation Manual attached to the
outdoor unit.
Veuillez lire attentivement ce Manuel d'installation avant d'installer le climatiseur.
• Ce manuel décrit la procédure d'installation de l'unité intérieure.
• Pour installer l'unité extérieure, reportez-vous au Manuel d'installation fourni avec
l'unité extérieure.
Bitte lesen Sie dieses Handbuch sorgfältig, bevor Sie mit der Installation des Klimagerätes beginnen.
• In diesem Handbuch wird die Installation der Raumeinheit beschrieben.
• Um die Außeneinheit zu installieren, folgen Sie den Anweisungen in dem Handbuch, das der Außeneinheit beiliegt.
Prima di installare il condizionatore d'aria, leggere con attenzione questo manuale d'installazione.
• Questo manuale descrive il metodo d'installazione dell'unità interna.
• Per l'installazione dell'unità esterna, fare riferimento al manuale d'installazione fornito insieme all'unità esterna.
Lea atentamente este Manual de instalación antes de proceder a la instalación del aparato de aire acondicionado.
• Este manual describe el método de instalación de la unidad interior.
• Para la instalación de la unidad exterior, consulte el Manual de instalación que acompaña a la unidad exterior.
Leia atentamente o presente Manual de Instalação antes de instalar o Ar Condicionado.
• O presente manual descreve o método de instalar a unidade interior.
• Para a instalação de uma unidade exterior, siga o Manual de Instalação que acompanha a unidade exterior.
Lees deze installatiehandleiding zorgvuldig door voordat u de airconditioner gaat installeren.
• Deze installatiemethode beschrijft de installatiemethode van de binnenunit.
• Zie voor de installatie van de buitenunit, de installatiehandleiding bij de buitenunit.
Παρακαλώ διαßάστε προσεχτικά το Ενχειρίδιο Ενκατάστασης πριν απ την ενκατασταση του Κλιµατιστικού.
• Το παρ ν Ενχειρίδιο περινράφει τη µέθοδο ενκατάστασης της εσωτερικής µονάδας.
• Για την ενκατάσταση της εξωθερικής µονάδας, ακολουθήστε το Ενχειρίδιο Ενκατάστασης που συνοδεύει
την εξωτερική µονάδα.
Outdoor Unit/Unité extérieure
Außengerät/Unità esterna
Unidad exterior/Unidade exterior
Buitenunit/Εξωτερική Μονάδα
RAV-SM562AT-E
RAV-SM802AT-E
INSTALLATION MANUAL
MANUEL D'INSTALLATION
INSTALLATIONS-HANDBUCH
MANUALE D'INSTALLAZIONE
MANUAL DE INSTALACIÓN
MANUAL DE INSTALAÇÃO
INSTALLATIEHANDLEIDING
ΕΓΧΕΙΡΙ∆ΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ

Advertisement

Table of Contents
loading

Summary of Contents for Toshiba RAV-SM562XT-E

  • Page 1 Raumeinheit/Unità interna Außengerät/Unità esterna Unidad interior/Unidade interior Unidad exterior/Unidade exterior Binnenunit/Εσωτερική Μονάδα Buitenunit/Εξωτερική Μονάδα RAV-SM562XT-E RAV-SM562AT-E RAV-SM802XT-E RAV-SM802AT-E Please read this Installation Manual carefully before installing the Air Conditioner. • This Manual describes the installation method of the indoor unit.
  • Page 2: Adoption Of New Refrigerant

    ADOPTION OF NEW REFRIGERANT • This Air Conditioner is a new type which adopts a new refrigerant HFC (R410A) instead of the conventional refrigerant R22 in order to prevent destruction of the ozone layer. • Discharge of refrigerant to atmosphere is illegal and may lead to prosecution. UTILISATION DU NOUVEAU REFRIGERANT •...
  • Page 3: Table Of Contents

    CONTENTS Accessory parts and Parts to be procured locally ....1 REFRIGERANT PIPING ............11 PRECAUTIONS FOR SAFETY ..........2 EVACUATING ............... 13 INSTALLATION PROCEDURE ..........4 ELECTRICAL WORK ............16 SELECTION OF INSTALLATION PLACE ......5 FINAL INSTALLATION CHECKS ........17 INSTALLATION OF INDOOR UNIT ........
  • Page 4: Parts To Be Procured Locally

    (6.35 mm (diam.), Nominal (diam.) 1/4" thick 0.8 mm) H07RN-F or 245IEC66 (1.5 mm or more) RAV-SM562XT-E, RAV-SM562AT-E Thermal insulation for refrigerant pipe (9.52 mm (diam.), Nominal (diam.) 3/8" thick 0.8 mm) (10 mm or more, thermal insulating foam polyethylene)
  • Page 5: Precautions For Safety

    PRECAUTIONS FOR SAFETY • Ensure that all Local, National and International regulations are satisfied. • Read this “PRECAUTIONS FOR SAFETY” carefully before Installation. • The precautions described below include the important items regarding safety. Observe them without fail. • After the installation work, perform a trial operation to check for any problem. Follow the Owner’s Manual to explain how to use and maintain the unit to the customer.
  • Page 6 PRECAUTIONS FOR SAFETY • After unpacking the unit, examine it carefully if there are possible damage. • Do not install in a place that might increase the vibration of the unit. • To avoid personal injury (with sharp edges), be careful when handling parts. •...
  • Page 7: Installation Procedure 4

    INSTALLATION PROCEDURE Installation Diagram of Indoor and Outdoor Units (Under Ceiling Installation) Pipe shield (Console Installation) (7) Sasa-Zeolite plus filter Hook (9) Filter frame (1) Installation plate (4) Mounting screw (8) Bio-enzyme & Gingko filter Air filter (14) Wireless remote controller (12) Pan head wood screw (11) Remote controller holder Before install the wireless...
  • Page 8: Selection Of Installation Place 5

    SELECTION OF INSTALLATION PLACE WARNING • Install the air conditioner where there is sufficient strength to withstand the weight of the unit. If the strength is not sufficient, the unit may fall down resulting in injury. CAUTION Upon approval of the customer, install the air conditioner in a place that satisfies the following conditions.
  • Page 9: Installation Of Indoor Unit

    INSTALLATION OF INDOOR UNIT Installation Place Before Installation • A place which provides the spaces around the indoor Remove the Air inlet grille unit as shown in the above diagram. • A place where there is no obstacle near the air inlet 1.
  • Page 10 INSTALLATION OF INDOOR UNIT 2. Set the Air inlet grille arm to the axis of the Front Install the indoor unit panel. 1. Remove the Side covers and the Installation plate (1). 3. Insert the Grille stopper to the correct position and fix 2.
  • Page 11 INSTALLATION OF INDOOR UNIT • How to install the Drain hose. • Other direction piping. 1. Remove the two screws and the Drain band. 1. Cut the slit of connecting only upper direction. 2. Cut a slit for the drain hose hole. Slit for upper piping Cover for rear upper piping...
  • Page 12 INSTALLATION OF INDOOR UNIT Install the indoor unit Console Installation • Install the Installation plate (1) at the wall according to • Select the terminal of Selector-SW from [C position] the Paper pattern. to [F position]. • Hang the indoor unit on the hooks of the Installation plate (1).
  • Page 13: Drain Piping Work

    DRAIN PIPING WORK Drainage 1. Run the Drain hose sloping downward. NOTE : • The hole should be made at a slight downward slant on the outdoor side. Console Installation Under Ceiling Installation 50 mm or more 50 mm or more NOTICE In case of upward drainage from the unit, (Under Ceiling Installation), it is necessary to use the Drain pump kit of separately sold optional part.
  • Page 14: Refrigerant Piping

    REFRIGERANT PIPING Refrigerant Piping 1. If the outdoor units are to be mounted on a wall, make sure that the platform supporting is sufficiently strong. The platform should be designed and manufactured to maintain its strength over a long period of time, and sufficient consideration should be given to ensuring that the outdoor unit will not fall.
  • Page 15 REFRIGERANT PIPING Tightening connection Pipe Shield for Flare Nut Connection Align the centers of the connecting pipes and tighten Joints in liquid and gas pipes of the indoor unit should the flare nut as far as possible with your fingers. Then be insulated with an attached Pipe shield (13).
  • Page 16: Evacuating

    EVACUATING NOTE : AIR PURGE • Use the vacuum pump, vacuum pump adapters, and Evacuate the air in the connecting pipe and in the gauge manifold referring to the manuals attached to indoor unit using vacuum pump. each tool before using them. Do not use the refrigerant in the outdoor unit.
  • Page 17 EVACUATING Heat insulation Cover 1. Provide heat insulation on the refrigerant piping on both the liquid side and gas side separately, and ensure that all joints in the insulation are completely sealed (without gap). 2. Since the temperature of the piping on the gas side Do not put the spanner or increases during heating operations, the heat torque wrench, etc.
  • Page 18 EVACUATING Compound pressure gauge Pressure gauge –101 kPa (–76 cmHg) Manifold valve Handle Lo Handle Hi (Keep fully closed) Charge hose (For R410A only) Charge hose Service port (Valve (For R410A only) core (Setting pin)) Vacuum pump adapter for counter-flow prevention (For R410A only) Vacuum pump...
  • Page 19: Electrical Work

    ELECTRICAL WORK For the air conditioner that has no power cord. NOTE : For selection and connection method of the power supply cords, refer to the details in the Installation Manual of the outdoor unit. CAUTION • If incorrect/incomplete wiring is carried out, it may cause an electrical fire or smoke.
  • Page 20: Final Installation Checks

    FINAL INSTALLATION CHECKS Precautions Test Operation 1. Ensure that the electrical cable used for power To switch the TEST RUN (COOL) mode, push supply and control of the system is unable to come TEMPORARY button for 10 sec. into contact with either service valves or piping work (The beeper will make a short beep.) which are not insulated.
  • Page 21 FINAL INSTALLATION CHECKS Useful Functions (SM802AT-E only) Self-Diagnosis by LED Indication In addition to the code checking by remote controller of the indoor unit, troubles of the outdoor unit can be diagnosed by LED indications on the cycle control P.C. board of the outdoor unit. Utilize them for various checks. For the check by remote controller of the indoor unit, refer to the installation Manual of the indoor unit.
  • Page 22: Environment

    ENVIRONMENT Environmental Issues Product maintenance 1. To minimize the chances of environmental damage and to ensure the efficient operation of the unit, it is recommended to have the air conditioner periodically checked and serviced by a qualified engineer. Product disposal 1.
  • Page 23 MEMO...