CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: ANSI Z21.88 • CSA 2.33 FOR VENTED GAS FIREPLACE HEATERS.
GDS26N

NATURAL GAS

GDS26P
PROPANE
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS.
SAFETY INFORMATION
WARNING
!
WARNING: If the information in these
instructions are not followed exactly, a fire
or explosion may result causing property
damage, personal injury or loss of life.
- Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier from
a neighbour's phone. Follow the gas
supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
-
Installation
and
performed by a qualified installer, service
agency or the supplier.
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031
$10.00
NorthlineExpress.com
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
OPERATION INSTRUCTIONS
service
must
www.napoleonfireplaces.com • ask@napoleon.on.ca
http://www.northlineexpress.com
INSTALLATION AND
be
1
W415-0607 / A / 01.18.08
Toll-Free 1-866-667-8454

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon Castlemore GDS26N

  • Page 1: Natural Gas

    Installation service must performed by a qualified installer, service agency or the supplier. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www.napoleonfireplaces.com • ask@napoleon.on.ca $10.00 W415-0607 / A / 01.18.08 NorthlineExpress.com http://www.northlineexpress.com...
  • Page 2: Table Of Contents

    TABLE of CONTENTS PG 3-5 INTRODUCTION BLOWER INSTALLATION Warranty NIGHT LIGHT REPLACEMENT General Instructions 22-23 FINISHING General Information Care of Glass and Plated Parts Glass Door Installation and Removal Dimensions Logo Placement 5-15 VENTING Glass Door Replacement Venting Lengths and Air Terminal Locations Switch Functions Vent Installations Log Placement...
  • Page 3: Warranty

    NAPOLEON® warrants its stainless steel burners against defects in workmanship and material for life, subject to the following conditions: During the fi rst 10 years NAPOLEON® will replace or repair the defective parts at our option free of charge. From 10 years to life, NAPOLEON®...
  • Page 4: General Instructions

    Provided that the clearance to combustibles are achieved, Standard ANSI/NFPA 501A in the United States. the most desirable and benefi cial location for a Napoleon® Objects placed in front of the stove must be kept a stove is in the centre of a building, thereby allowing the most minimum of 48"...
  • Page 5: Dimensions

    DIMENSIONS FIGURE 1a FIGURE 1b FIGURE 1c ” 7” DIA. 4” DIA. ” ” 37” LINE ACCESS ELECTRICAL ” ACCESS VENTING VENTING LENGTHS AND AIR TERMINAL LOCATIONS may be used on both the inner exhaust and the outer intake Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct vent pipe joints of all other approved vent systems except Temp or American Metal Amerivent venting components.
  • Page 6: Typical Vent Installations

    HORIZONTAL VENT SECTIONS: A minimum clearance VERTICAL VENT SECTIONS: A minimum of 1" of 1" at the bottom and sides and 2" at the top of the all around the vent pipe on all vertical runs to vent pipe in all horizontal runs to combustibles is combustibles is required.
  • Page 7: Minimum Air Terminal Location Clearances

    MINIMUM AIR TERMINAL LOCATION CLEARANCES FIGURE 6 W415-0607 / A / 01.18.08 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 8 W415-0607 / A / 01.18.08 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 9 DEFINITIONS ELBOW VENT LENGTH VALUES for the following symbols used in the venting calculations feet inches and examples are: 1° 0.03 > - greater than 15° 0.45 > - equal to or greater than 30° 11.0 < - less than 45°...
  • Page 10 TOP EXIT / HORIZONTAL TERMINATION ) > (V Example 2: Simple venting confi guration = 6 ft FIGURE 9 (only one 90° elbow) = 3 ft = 5 ft = 3 + 5 = 8 ft = .03(two 90° elbows - 90°) = .03(180° - 90°) = 2.7 ft = 8 + 2.7 = 10.7 ft = 10.7 + 6 =16.7 <...
  • Page 11 REAR EXIT / HORIZONTAL TERMINATION Example 4: ) < (V Simple venting confi guration 90° (only two 90° elbows) 90° 90° FIGURE 12 90° FIGURE 13 See graph to determine the required vertical rise V for the required horizontal run H = 9 ft = 6 ft REQUIRED...
  • Page 12 REAR EXIT / HORIZONTAL TERMINATION Example 5: ) > (V Simple venting confi guration (only two 90° elbows) 90° FIGURE 14 90° 90° 45° 90° FIGURE 15 See graph to determine the required vertical rise V for the required horizontal run H = 4 ft = 1.5 ft = 4 + 1.5 = 5.5 ft...
  • Page 13 TOP OR REAR EXIT VERTICAL TERMINATION ) < (V Example 6: Simple venting confi gurations FIGURE 16 FIGURE 17 90° 90° 90° 90° See graph to determine the required vertical rise V for the required horizontal run H = 5 ft = 6 ft = 10 ft REQUIRED...
  • Page 14: Vertical Through Existing Chimney

    When installing the unit to this system, Duravent vent PIPE components must be used. You must start with a Duravent VENT adaptor, GDS924N, directly off the unit. The GDS924N is only PIPE available at your Napoleon® dealer. 40 FEET MAXIMUM 3 FEET MINIMUM FIGURE 18 W415-0607 / A / 01.18.08...
  • Page 15: Rear Exit Conversion

    REAR EXIT CONVERSION In order to convert the venting confi guration from a top exit to a rear exit, remove components as illustrated: When reinstalling in the alternate position: Check gaskets for tears, replace if necessary to ensure a proper seal. FIGURE 19 Outer Top 7”...
  • Page 16 INSTALLATION WALL AND CEILING PROTECTION For optimum performance, it is recommended that VERTICAL INSTALLATION horizontal runs have a minimum 1" rise per foot when using Simpson Dura-Vent, Selkirk Direct Temp, 1. Determine the air terminal location, cut and frame a 9" American Metal Amerivent, or Wolf Steel rigid or square opening in the ceiling and the roof to provide the fl...
  • Page 17 STOVE VENT CONNECTION 1. Attach the telescopic sleeve to the last section of 7" rigid vent pipe. Secure FIGURE 23 7” RIGID with screws and high temperature sealant W573-0002 (not supplied). VENT PIPE 2. Install the 4" fl exible vent pipe to the stove. Secure with 3 screws and fl at 4”...
  • Page 18 EXTENDED HORIZONTAL AND CORNER AIR TERMINAL INSTALLATION FIGURE 26 1. Follow the instructions for "Horizontal Air Terminal Installations", items 1 to 3. 2. Continue adding components alternating fl exible and rigid vent pipes. Ensure that all 4" fl exible vent pipes and elbows have suffi cient vent spacers attached and each component is securely fastened to the one prior.
  • Page 19 Conversion Kits The mobile home appliance is fi eld convertible between Natural Gas (NG) and Propane (LP). To convert from one gas to another consult your Napoleon® dealer/distributor. W415-0607 / A / 01.18.08 NorthlineExpress.com http://www.northlineexpress.com...
  • Page 20 MINIMUM CLEARANCES TO COMBUSTIBLES Minimum clearance to combustible construction from stove and vent surfaces: BACK WALL 2" 5" 2" 1" to bottom and sides of the vent pipe* 2" to top of the vent pipe* Rear Exit 47 1/2" to ceiling from base of the unit BACK WALL Top Exit 51"...
  • Page 21: Blower Installation

    BLOWER INSTALLATION ELECTRICAL INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 in Canada CANADIAN ELECTRICAL CODE or the current ANSI/NFPA 70 in the United States.
  • Page 22: Finishing

    FINISHING GLASS DOOR INSTALLATION AND REMOVAL 1. Lift the top cast piece off of the unit. 2. Pull handle forward and rotate 90º to unlatch the door. FIGURE41a Figure 41a. 3. Lift door straight up to remove. Figure 41b. 90° FIGURE41b DOOR LOGO PLACEMENT...
  • Page 23: Switch Functions

    fl ame. Use only certifi ed "glowing embers" and Phazer logs available from your Napoleon® dealer. 3. Place the center log as shown, ensuring the holes on the underside are placed onto the two center pins.
  • Page 24: Wiring Diagram

    WIRING DIAGRAM The main burner on/off switch and Night Light switch is Route 2-strand (solid core) wire through the electrical hole located behind lower access panel. For ease of accessibility, located at the bottom left side of the unit. Connect the optional remote wall switches may be installed in a convenient wires from the wall switch to the two corresponding spade location for both burner and light operation.
  • Page 25: Operation / Maintenance

    A 5-10 second total light-up period is satisfactory. If ignition ® remove the logs exposing both assemblies. takes longer, consult your Napoleon dealer/distributer. 2. Keep the control compartment, logs, burner, air shutter 7. Check that the door gasketing is not broken or missing.
  • Page 26: Adjustments

    ADJUSTMENTS PILOT INJECTOR AND ORIFICE REPLACEMENT 1. Turn off the electrical and NOTE: Check and adjust, if necessary, the primary air gas supply to the stove. ” for propane and ” for natural gas. Replace the 2. Remove the cast front, screws.
  • Page 27: Replacements

    Contact your dealer for questions concerning prices and WARNING availability of replacement parts. Normally all parts can be ordered through your Napoleon® dealer or distributor. When ordering replacement parts always give the following Failure to position the parts in accordance with these diagrams or...
  • Page 28 W415-0607 / A / 01.18.08 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 29: Trouble Shooting Guide

    TROUBLE SHOOTING GUIDE EFORE ATTEMPTING TO TROUBLESHOOT PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED SYMPTOM PROBLEM TEST SOLUTION Pilot will not light. - Wiring Verify the "S" wire for the sensor and the "I" wire for the ignitor are Makes noise with no connected to the correct terminals (not reverse) on the module and spark at pilot burner...
  • Page 30 SYMPTOM PROBLEM TEST SOLUTION Inspect all wires, ensure good tight connections. Verify that all - Wiring / Connection Pilot lights wiring is installed exactly as specifi ed. Stops sparking / pilot remains lit Inspect the wiring harness, and verify the harness is tightly con- - Wiring harness but burner will nected to the module.
  • Page 31 W415-0607 / A / 01.18.08 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...
  • Page 32 NOTES W415-0607 / A / 01.18.08 NorthlineExpress.com http://www.northlineexpress.com Toll-Free 1-866-667-8454...