10-7. TEST POINT DIAGRAM AND VOLTAGE
1. Indoor electronic control P.C. board, Indoor terminal P.C. board, Power monitor receiver SW P.C. board
MSZ-GF60VE MSZ-GF71VE
Indoor terminal P.C. board
Fuse
Terminal
Varistor
block
(F11)( )
(NR11)
Power monitor receiver SW P.C. board
Please replace the fuse after removing the indoor terminal P.C. board from the electrical box.
OBH634
Indoor electronic control P.C. board
Indoor coil thermistor
RT12, RT13
12 VDC
(CN112)
Room temperature
thermistor RT11
(CN111)
Vane motor
(CN151,CN152)
Emergency
operation switch
Timer short mode point
(E.O. SW)
JPG JPS (Refer to 8-1.)
(SW1)
To disable "Auto restart func-
tion" cut the Jumper wire to
JR77. (Refer to 8-3.)
5 VDC
31
Interlock switch
Resistor
(FAN) (CN1R1)
(R111)
Indoor fan motor
(CN211)
325 VDC
(–) GND
(high-voltage DC)
15 VDC
(+)3-6 VDC
(+)0 or 15 VDC
Room temperature thermistor (RT11)
Indoor coil thermistor (RT12, RT13)
Temperature (°C)