nokia
C
P
ONNECTING
EOPLE
NMP/CMO Sales and Marketing
Customer Care EMEA
Technical Services, Repair Concepts
To avoid damage of B-Cover Lower see also video clip
on Care Point. Remove the Vibra Retainer by using a
slotted screwdriver as a lever.
Take away the Microphone by using the dental tool.
9.
DOMESHEET EXCHANGE
Protect the UI Adhesive.
Take care about LEDs on the UI PWB Module during
removal of the Domesheet.
Service Manual 7200 Level 1&2
PAGE 13 (24)
Confidential
Vibra Motor can be removed easy. Take care of the
right position when assembling.
Tweezers can be used to remove the DC-Jack. Take
care not to damage spring contacts.
Remove the faulty Domesheet by lifting it up carefully
from UI PWB Module.
Clean the pads on the PWB Module with a clean cloth if
necessary. Be carefully not damage the components
on the PWB.
Copyright 2003-2004 © Nokia Corporation
Approved 1.0
DJk
03.03.2004