free hit counter

Mitsubishi Electric MXZ-2C30VA Service Manual page 365

Outdoor unit
Hide thumbs Also See for MXZ-2C30VA:
Table of Contents

Advertisement

MXZ-6C122VA HEATING
Indoor units
combination
Unit A
20+20+20+35
2.23
20+20+20+42
2.35
20+20+20+50
2.31
20+20+20+60
2.15
20+20+20+71
1.98
20+20+22+22
2.62
20+20+22+25
2.60
20+20+22+35
2.41
20+20+22+42
2.40
20+20+22+50
2.32
20+20+22+60
2.15
20+20+22+71
1.98
20+20+25+25
2.56
20+20+25+35
2.40
20+20+25+42
2.36
20+20+25+50
2.26
20+20+25+60
2.11
20+20+25+71
1.94
20+20+35+35
2.22
20+20+35+42
2.17
20+20+35+50
2.10
20+20+35+60
1.96
20+20+35+71
1.81
20+20+42+42
2.10
20+20+42+50
2.00
20+20+42+60
1.86
20+20+42+71
1.73
20+20+50+50
1.89
20+20+50+60
1.76
20+20+50+71
1.64
20+20+60+60
1.65
20+20+60+71
1.54
20+22+22+22
2.81
20+22+22+25
2.74
20+22+22+35
2.48
20+22+22+42
2.42
20+22+22+50
2.32
20+22+22+60
2.13
20+22+22+71
1.96
20+22+25+25
2.67
20+22+25+35
2.43
20+22+25+42
2.37
20+22+25+50
2.26
20+22+25+60
2.08
20+22+25+71
1.91
20+22+35+35
2.25
Heating Capacity (kW)
Unit B
Unit C
Unit D
Unit E
2.00
2.00
3.50
-
1.96
1.96
4.12
-
1.85
1.85
4.64
-
1.73
1.73
5.20
-
1.60
1.60
5.69
-
2.00
2.20
2.20
-
2.00
2.20
2.50
-
2.00
2.20
3.50
-
1.94
2.14
4.08
-
1.82
2.00
4.55
-
1.70
1.88
5.11
-
1.59
1.75
5.66
-
2.00
2.50
2.50
-
2.00
2.50
3.50
-
1.89
2.36
3.96
-
1.79
2.24
4.48
-
1.66
2.08
4.99
-
1.56
1.95
5.53
-
1.85
3.25
3.25
-
1.76
3.08
3.70
-
1.66
2.91
4.16
-
1.57
2.75
4.71
-
1.47
2.57
5.20
-
1.68
3.52
3.52
-
1.61
3.37
4.02
-
1.51
3.16
4.52
-
1.40
2.94
4.97
-
1.53
3.82
3.82
-
1.43
3.57
4.28
-
1.34
3.35
4.76
-
1.35
4.05
4.05
-
1.26
3.79
4.48
-
2.20
2.20
2.20
-
2.20
2.20
2.50
-
2.20
2.20
3.50
-
2.10
2.10
4.00
-
1.97
1.97
4.47
-
1.85
1.85
5.03
-
1.73
1.73
5.57
-
2.20
2.50
2.50
-
2.16
2.45
3.43
-
2.06
2.34
3.93
-
1.94
2.20
4.40
-
1.82
2.07
4.96
-
1.71
1.94
5.51
-
2.00
3.19
3.19
-
Outdoor unit
power consumpution (kW)
Unit F
Total
10.60
2.627
-
(3.20-14.20)
(0.780-4.140)
12.00
3.070
-
(3.20-14.90)
(0.760-4.250)
12.70
3.490
-
(3.20-15.00)
(0.760-4.720)
12.90
3.610
-
(3.20-15.00)
(0.760-4.720)
13.00
3.670
-
(3.20-15.00)
(0.760-4.720)
11.00
2.717
-
(3.20-14.40)
(0.770-4.100)
11.30
2.780
-
(3.20-14.60)
(0.760-4.070)
11.70
2.940
-
(3.20-14.80)
(0.760-4.180)
12.50
3.370
-
(3.20-14.90)
(0.760-4.250)
13.00
3.670
-
(3.20-15.00)
(0.760-4.720)
13.10
3.730
-
(3.20-15.00)
(0.760-4.720)
13.20
3.760
-
(3.20-15.00)
(0.760-4.720)
11.50
2.850
-
(3.20-14.60)
(0.760-4.050)
12.00
3.070
-
(3.20-14.90)
(0.760-4.250)
12.60
3.430
-
(3.20-14.90)
(0.760-4.250)
13.00
3.670
-
(3.20-15.00)
(0.760-4.720)
13.20
3.790
-
(3.20-15.00)
(0.760-4.720)
13.20
3.760
-
(3.20-15.00)
(0.760-4.720)
12.20
3.190
-
(3.20-14.90)
(0.760-4.250)
12.70
3.490
-
(3.20-15.00)
(0.760-4.720)
13.10
3.730
-
(3.20-15.00)
(0.760-4.720)
13.20
3.760
-
(3.20-15.00)
(0.760-4.720)
13.20
3.750
-
(3.20-15.00)
(0.760-4.720)
13.00
3.670
-
(3.20-15.00)
(0.760-4.720)
13.20
3.750
-
(3.20-15.00)
(0.760-4.720)
13.20
3.700
-
(3.20-15.00)
(0.760-4.720)
13.20
3.650
-
(3.20-15.10)
(0.760-4.500)
13.20
3.630
-
(3.20-15.10)
(0.760-4.500)
13.20
3.600
-
(3.20-15.10)
(0.760-4.500)
13.20
3.600
-
(3.20-15.10)
(0.760-4.500)
13.20
3.600
-
(3.20-15.10)
(0.760-4.500)
13.20
3.600
-
(3.20-15.10)
(0.760-4.500)
12.10
3.130
-
(3.20-14.90)
(0.760-4.250)
12.20
3.190
-
(3.20-14.90)
(0.760-4.250)
12.30
3.250
-
(3.20-14.90)
(0.760-4.250)
12.80
3.550
-
(3.20-15.00)
(0.760-4.720)
13.20
3.780
-
(3.20-15.00)
(0.760-4.720)
13.20
3.760
-
(3.20-15.00)
(0.760-4.720)
13.20
3.720
-
(3.20-15.00)
(0.760-4.720)
12.30
3.250
-
(3.20-14.90)
(0.760-4.250)
12.40
3.310
-
(3.20-14.90)
(0.760-4.250)
12.90
3.610
-
(3.20-15.00)
(0.760-4.720)
13.20
3.760
-
(3.20-15.00)
(0.760-4.720)
13.20
3.750
-
(3.20-15.00)
(0.760-4.720)
13.20
3.710
-
(3.20-15.00)
(0.760-4.720)
12.60
3.430
-
(3.20-15.00)
(0.760-4.720)
235/266
Current
Power
(A)
factor (%)
11.54
99
13.48
99
15.33
99
15.85
99
16.12
99
11.93
99
12.21
99
12.91
99
14.80
99
16.12
99
16.38
99
16.51
99
12.52
99
13.48
99
15.06
99
16.12
99
16.64
99
16.51
99
14.01
99
15.33
99
16.38
99
16.51
99
16.47
99
16.12
99
16.47
99
16.25
99
16.03
99
15.94
99
15.81
99
15.81
99
15.81
99
15.81
99
13.75
99
14.01
99
14.27
99
15.59
99
16.60
99
16.51
99
16.34
99
14.27
99
14.54
99
15.85
99
16.51
99
16.47
99
16.29
99
15.06
99

Advertisement

Table of Contents
loading

Table of Contents