General purpose corded handheld linear bar code reader (235 pages)
Summary of Contents for Datalogic QuickScan Mobile
Page 1
QuickScan™ Mobile General Purpose Handheld Linear Imager Bar Code Reader with Datalogic’s STAR Cordless System™ Quick Reference Guide...
Page 2
An Unpublished Work - All rights reserved. No part of the contents of this docu- mentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic ADC, Inc. or its subsidiaries or affiliates ("Datalogic" or "Datalogic ADC"). Owners of Data-...
Hands-Free Use ..................2 Using Your QuickScanTM Mobile Reading System ......3 Installing the Battery ..................3 Changing the Batteries ................5 Connecting the QuickScan Mobile ..............7 System Connections ................7 QuickScan Mobile Cradle Configuration ............. 10 Serial/USB-COM Configuration ............10 QuickScan Mobile Reader Configuration ............
Using Quickscan™ Mobile Reader and Cradle The QuickScan Mobile reader and cradle build a Cordless Reading System for the collection, decoding and transmission of barcode data. Standard models can be connected to a Host PC through a USB, RS-232, Wedge or Pen emulation cable. All models are suited for single-cradle layouts.
Successful reading is indicated by an audible tone. Good read LED Not Recommended Hands-Free Use When using the QuickScan Mobile on the cradle, remember to lock the reader by pushing up the locking system as indicated in the following figure. QuickScan™ Mobile...
Connect a QuickScan Mobile cradle to the Host. For installation and connection information see "System Connections" on page Insert the QuickScan Mobile reader into the cradle to start the battery charging. A full charge of the Lithium battery takes 3.5 – 6 hours.
Page 8
Always charge the battery at 32° – 113°F (0° - 45°C) temperature range. Use only the authorized power supplies, battery pack, chargers, and docks supplied by your Datalogic reseller. The use of any CAUTION other power supplies can damage the device and void your war- ranty.
Installing the Battery The typical manufacturer advertised useful life of LI batteries is one to three years, depending on usage and number of charges, etc., after which they should be removed from service, especially in mission critical applications. Do not continue to use a battery that is showing excessive loss of capacity, it should be properly recycled / disposed of and replaced.
Page 10
Installing the Battery Re-insert the cover in the handle, and replace the screw to secure it. Do not incinerate, disassemble, short terminals or expose to high temperature. Risk of fire, explosion. Use specified charger only. Risk of explosion if the battery is replaced by an incorrect type.
Connect the appropriate interface cable to the cradle by simply plugging it into the Host connector on the base of the cradle. Figure 2. QuickScan Mobile Cradle - Bottom View To disconnect the cable, insert a paper clip or other similar object into the hole corresponding to the connector on the base of the cradle.
Page 12
Connecting the QuickScan Mobile IBM USB POS WEDGE (Only for Quickscan M2 type:130) WEDGE (Only for QUICKSCAN M2 TYPE:130) QuickScan™ Mobile...
Page 13
Connecting the QuickScan Mobile IBM PORT9B / IBM Port 5B (Only for QUICKSCAN M2 TYPE:110) CAB-445 CAB-446 Quick Reference Guide...
USB-COM interface or by reading configuration barcodes with the reader. Serial/USB-COM Configuration By connecting the QuickScan Mobile cradle to a PC through an RS-232 or USB cable (only USB-COM interface) it is possible to send configuration strings from the PC to the reader. Using this method you can also send new configuration strings from the PC to the reader or upgrade application software onto the reader.
Page 15
Bind Ì$+RN0$-IÎ The green LED on the QuickScan Mobile reader will blink: the reader is ready to be positioned onto the cradle. Firmly position the reader onto the cradle within 10 seconds, a beep will be emitted, signaling that the QuickScan Mobile cradle has been paired to the QuickScan Mobile reader.
O.S. and should therefore be selected from the dialog box (the first time only). You can now read codes with the associated QuickScan Mobile reader. At this point you can read the USB interface configuration code according to your application.
When configuring USB-COM, the relevant files and drivers must be installed from the USB Device Installation software, which can be downloaded from the web site http:// www.datalogic.com. Select one keyboard nationality code from the table at page 18. Quick Reference Guide...
RS-232 Interface Selection RS-232 Interface Selection Read the QuickScan Mobile cradle restore default code, and then read the interface selection code for your application: RESTORE QUICKSCAN MOBILE CRADLE DEFAULT Ì$+RX0$-qÎ RS-232 Interface Standard Ì$+CP0$-$Î POS TERMINALS Nixdorf Mode A Ì$+CM2EC0$->Î...
This feature is only available for Quickscan M2 Type:130 Read the QuickScan Mobile cradle restore default code, then read the interface selection code for your application: RESTORE QUICKSCAN MOBILE CRADLE DEFAULT Ì$+RX0$-qÎ WEDGE INTERFACE IBM AT or PS/2 PCs Ì$+CP500$-aÎ...
Page 20
Wedge Interface Selection WEDGE INTERFACE (CONTINUED) IBM Terminals 31xx, 32xx, 34xx, 37xx: To select the interface for these IBM Terminals, read the correct KEY TRANSMISSION code. Select the KEYBOARD TYPE if necessary (default = advanced keyboard). KEY TRANSMISSION MODE make-only keyboard Ì$+CP502$-oÎ...
Page 21
Wedge Interface Selection WEDGE INTERFACE (CONTINUED) WYSE TERMINALS ANSI Keyboard Ì$+CP509$-9Î PC Keyboard Ì$+CP510$-gÎ ASCII Keyboard Ì$+CP511$-nÎ VT220 style Keyboard Ì$+CP514$-ÇÎ DIGITAL TERMINALS VT2xx/VT3xx/VT4xx Ì$+CP512$-uÎ APPLE APPLE ADB Bus Ì$+CP513$-|Î Quick Reference Guide...
Wedge Interface Selection USB / Wedge Keyboard Nationality USB/Wedge interface users should select one of the following KEYBOARD NATIONALITY codes. Belge Ì$+FJ7$-8Î Deutsch Ì$+FJ3$-$Î English (UK) Ì$+FJ4$-)Î Español Ì$+FJ6$-3Î Français Ì$+FJ2$-ÊÎ Italiano Ì$+FJ1$-ÅÎ Svenskt Ì$+FJ5$-.Î Ì$+FJ0$-|Î The following Keyboard Nationality selection is only valid for IBM AT compatible PCs: Japanese Ì$+FJ8$-=Î...
IBM46xx Interface Selection This feature is only available for Quickscan M2 Type:110 Read the QuickScan Mobile cradle restore default code, then read the interface selection code for your application: RESTORE QUICKSCAN MOBILE CRADLE DEFAULT Ì$+RX0$-qÎ IBM 46XX TERMINALS PORT 9B 4501 Protocol Ì$+CP800$-pÎ...
IBM46xx Interface Selection Pen Interface Selection Read the QuickScan Mobile cradle restore default code, then read the interface selection code for your application: RESTORE QUICKSCAN MOBILE CRADLE DEFAULT Ì$+RX0$-qÎ PEN INTERFACE Ì$+CP6$-BÎ QuickScan™ Mobile...
YOUR SYSTEM IS READY TO READ CODES AND TO SEND THE DATA TO THE HOST. To change the defaults, refer to the "QuickScan Mobile Reference Manual", part number 820001971, or to the Datalogic Aladdin™ Configuration program, both downloadable from the website. Quick Reference Guide...
Reader Default Configuration Reader Default Configuration DATA FORMAT code identifier disabled (enabled for POS terminals), field adjustment disabled, code length tx not transmitted, character replacement disabled, address stamping disabled; address delimiter disabled POWER SAVE sleep state/USB suspend disabled, enter sleep timeout = 0.6 sec READING PARAMETERS hand-held operation = hardware trigger, stand operation = automatic, trigger active level, no timeout, Flash On = 1 sec, Flash Off = 0.6 sec, one read per...
Illuminator LED array Wavelength 630 ~ 670 nm Max. LED Output Power 0.33 mW LED safety class Class 1 EN 60825-1 Reading field see reading table Max. resolution 0.10 mm, 4 mils PCS minimum 20% (Datalogic Test Chart) QuickScan™ Mobile...
Page 29
Technical Features Environmental Features – READER 0° to + 40 ° C (32° to 104 °F) Working Temperature Storage Temperature -20° to 70 °C (-4° to 158 °F) (without battery) Humidity 90% non condensing IEC 68-2-32 Test ED 1.5 m (4 ft 9 in) Drop resistance Protection class IP30...
FCC Compliance Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment. This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation.
Compliance - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. LED Class QuickScan Mobile Product Label Class 1 LED product. EN60825-1:(2001) Radio Compliance Contact the competent authority responsible for the management of radio...
Page 32
Compliance China RoHS Table of Restricted Elements (Scanner) QuickScan™ Mobile...
Page 33
Compliance China RoHS Table of Restricted Elements (Base) Quick Reference Guide...
Waste Electrical and Electronic Equipment (WEEE) Statement English For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the website at www.datalogic.com. Italian Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche consultare il sito Web www.datalogic.com.
Datalogic service center, with ship- ping charges prepaid. Datalogic shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Datalogic service center is located.
DAMAGES. Risk of Loss Customer shall bear risk of loss or damage for product in transit to Datalogic. Datalogic shall assume risk of loss or damage for product in Datalogic’s possession. In the absence of spe- cific written instructions for the return of product to Customer, Datalogic will select the car- rier, but Datalogic shall not thereby assume any liability in connection with the return shipment.
Services and Support Services and Support Datalogic provides several services as well as technical support through its website. Log on to www.datalogic.com and click on the links indicated for fur- ther information. Products Search through the links to arrive at your product page where you can down-...
Page 38
Services and Support NOTES QuickScan™ Mobile...
Lippo di Calderara di Reno (BO) 40012 Italy Pag.: 1 di 1 La presente dichiarazione di conformità è rilasciata sotto la responsabilità esclusiva di Datalogic ADC Srl per: This Declaration of Conformity is issued under the sole responsibility of Datalogic ADC Srl for: Cette déclaration de conformité...