Adjustable Lintel - Town & Country Fireplaces TCWS38 D SERIES Installation And Operating Instructions Manual

Modular direct vent fireplace
Table of Contents

Advertisement

2. Attach the Assembled Frame to the Unit
Attach the framing kit to the unit.
(Fig. #16).
3. Secure to Existing Framing
Bend out the tabs 90 degrees before
inserting the unit into its framed housing
(Fig. #17).
Secure the frame assembly to the wood
frame through the tabs.
NON COMBUSTIBLE
BOARD
This replace may be recessed up to a
maximum depth of 6" , this recess must
be constructed from non combustible
material. The space between the
outside lintels and the rebox must be
completely free of any debris and the
window with trim tted must be able
to move freely. No building material
is permitted to protrude past the lintel
bars attached to the replace under
ANY circumstance.
4. Install Non-Combustible Board
Use drywall screws, #8, to install the
non-combustible board(Fig. #18).
Fig. #18

Adjustable Lintel

NON-COMBUSTIBLE
FINISH MATERIAL
Fig. #16
Fig. #17
Fig. #19
Non combustible building
material may not extend
past this point
12
Area inside Lintel must
remain free of obstructions
TCWS38_D 011214-48