free hit counter

Firebox Panels Installation - Town & Country Fireplaces TCWS38 D SERIES Installation And Operating Instructions Manual

Modular direct vent fireplace
Table of Contents

Advertisement

Firebox Panels Installation

1.
Remove the side panel retainers located on the underside of the rebox heat
shield. The retainers are each held in place by one screw.(Fig. #55)
2. Insert the back panel into the rebox by tilting the panel and rest the panel on
the seat tabs at the back of the rebox. (Fig. #51 & 52)
NOTE: Centering tabs on the panel should be located inside the slots in the
support tabs..
3. While supporting the back panel insert the left side panel into the rebox.
Position the top of the panel against the side of the unit. (Fig. #52)
4. Reinstall left side retainer.
NOTE: Notch at bottom of side panel faces to front of unit.
NOTE: Install burner now.
5. Install the Right side panel in the same manners as the Left side being sure
to tuck the lighting wires into the space in the rear corner.
6. Reinstall the Right side panel retainer.(Fig.#55)
7.
Place the front panel on the front lip of the rebox, wide ange facing the
center of the replace. (Fig. #53a & #53b)
Fig #53b
TCWS38_D 011214-48
WIDE EDGE TO CENTER OF
FIREPLACE
Fig. #51
Fig. #52
Fig. #53a