free hit counter

Connecting Relay Modules, Powerline Carrier Devices And Output Triggers; 4204/4229 Relay Modules; Powerline Carrier Devices - Honeywell ADEMCO VISTA SERIES VISTA-21iP Installation And Setup Manual

Hide thumbs Also See for ADEMCO VISTA SERIES VISTA-21iP:
Table of Contents

Advertisement

Connecting Relay Modules, Powerline Carrier Devices and Output Triggers

4204/4229 Relay Modules

U L
For UL installation
requirements, refer to the
Installation Instructions for
the 4204.
Powerline Carrier
Devices
U L
Powerline Carrier
devices and the 1361X10
Transformer are not UL
Listed for fire or burglary
functions and are intended
for home automation.
1. Mount either remotely or in the control panel cabinet.
2. Connect each module to the control's keypad terminals and set the device addresses
as previously described in the Connecting Keypads and Other Addressable
Device section. Use the connector harness supplied with the module. Use standard
4-conductor twisted cable for long wiring runs.
• Up to 16 relays (if no powerline carrier devices are used)
3. Connect the desired field wiring to the unit's relay contact terminals.
4204
DIP SWITCH
FOR SETTING DEVICE ADDRESS
AND ENABLING/DISABLING TAMPER
COVER TAMPER (REED) SWITCH
Figure 13. 4204 Connections to Control
• Supervision: 4204 and 4229 modules are supervised against removal. The module's
device address is displayed as follows if a module is disconnected from the control's
terminals, or if the module cover is removed and the tamper jumper is installed:
Alpha: CHECK xx Wire Expansion
FAULT xx Wire Expansion
ALARM xx Wire Expansion
Fixed-Glass: lxx (or 91 if field *199 set for 2-digit display)
where "xx is the module's address.
• If communication/tamper failure occurs on a device with zones wired to it, all zones on
the device will be displayed in their respective partitions.
1. Install the powerline carrier devices according to the instructions included with each.
• Up to 16 devices (if no relays are used)
2. Use Programming Mode to enter the device house ID in data field*27, and enter the
unit code using *79 Output Device menu Mode.
3. See connections diagram in the AC Wiring section for connecting the 1361X10
transformer to the triggers.
• You must use a 1361X10 Transformer instead of the 1361 Transformer.
• The 1361X10 Transformer provides AC power to the control panel, and also supplies
signals from the control panel through the premises AC wiring to the Powerline
Carrier devices (which are plugged into AC outlets). You can then make devices that
are plugged into Powerline Carrier devices perform various functions in response to
commands you enter at the security system keypads.
Canada: Use the PSC04 Powerline Interface as shown below.
8-PIN TRIGGER CONNECTOR
1
3
4
5
6
7
8
SA4120XM-1 CABLE
SYNC
COM
DATA
Figure 14. PSC04 Powerline Interface Connections
RELAY
4
TYPICAL
(SHOWN "OFF")
4-PIN TOUCHPAD PLUG
EITHER OR BOTH
CAN BE USED
TB1
13 14 15 16
DATA IN
YEL
FROM CONTROL
BLK
(–) GROUND
GRN
DATA OUT
TO CONTROL
RED
(+) 12V
BLK
GRN
RED
YEL
(for Canadian Installations)
Programming Overview
C
NC
NO
C
RELAY
3
NC
NO
C
RELAY
2
NC
NC
NO
C
RELAY
1
NC
NO
TB2
4204_conn-1-V0
X-10 PSC04
POWERLINE INTERFACE
1 2 3 4
MODULAR PHONE CORD (not supplied)
1 - BLACK
2 - RED
3 - GREEN
4 - YELLOW
2-11

Advertisement

Table of Contents
loading