free hit counter

Lenovo x3550 M4 Installation And Service Manual page 235

Hide thumbs Also See for x3550 M4:
Table of Contents

Advertisement

2. Turn off the server and peripheral devices and disconnect the power cords and
all external cables.
3. Remove the filler panel from the empty drive bay.
4. Touch the static-protective package that contains the drive to any unpainted
metal surface on the server; then, remove the drive from the package and place
it on a static-protective surface.
5. Install the hard disk drive in the drive bay:
a. Grasp the black drive handle and slide the blue release latch to the right
and align the drive assembly with the guide rails in the bay.
Figure 121. 2.5-inch simple-swap hard disk drive installation
Figure 122. 3.5-inch simple-swap hard disk drive installation
b. Gently push the drive into the bay until the drive stops.
6. Reinstall the drive bay filler panel that you removed earlier.
7. If you are installing additional simple-swap hard disk drives, do so now.
8. Turn on the peripheral devices and the server.
Drive IDs:
The drive ID that is assigned to each drive is printed on the front of the server.
The following illustrations show the locations of the IDs of the drives. The ID
numbers and the drive bay numbers are the same.
2.5-inch simple-swap hard disk drive IDs:
The simple-swap-drive ID that is assigned to each drive is printed on the front of
the server.
The following illustration shows the location of the IDs of the hard disk drives.
The ID numbers and the drive bay numbers are the same.
Chapter 6. Removing and replacing components
217

Advertisement

Table of Contents
loading

Table of Contents