Procedure
Figure 158. ServeRAID memory module installation
10. Turn on the peripheral devices and the server.
Removing the dual-port network adapter
Use this information to remove the dual-port network adapter.
About this task
To remove the dual-port network adapter, complete the following steps:
Procedure
1. Read the safety information that begins on "Safety" on page vii and
2. Turn off the server and peripheral devices and disconnect the power cords and
3. Remove the cover (see "Removing the cover" on page 36).
4. Remove the PCI riser-card assembly (if installed) from PCI riser connector 2
5. Loosen the two captive screws on the network adapter from the screw holes on
252
System x3550 M4 Type 7914: Installation and Service Guide
1. Read the safety information that begins on "Safety" on page vii and
"Installation guidelines" on page 33.
2. Turn off the server and peripheral devices and disconnect all power cords.
3. Remove the cover (see "Removing the cover" on page 36).
4. Remove the ServeRAID SAS/SATA controller (see "Removing a ServeRAID
SAS/SATA controller" on page 245).
5. Align the memory module with the connector on the ServeRAID adapter and
push it into the connector until it is firmly seated.
6. Reinstall the ServeRAID SAS/SATA controller (see "Replacing a ServeRAID
SAS/SATA controller" on page 246).
7. Reconnect the power cords and any cables that you removed.
8. Reinstall the cover (see "Replacing the cover" on page 203).
9. Slide the server into the rack.
"Installation guidelines" on page 33.
all external cables, if necessary.
(see "Removing a PCI riser-card assembly" on page 236).
the system board.