Lenovo x3550 M4 Installation And Service Manual page 374

Hide thumbs Also See for x3550 M4:
Table of Contents

Advertisement

80010002-0701ffff • 80010204-1d03ffff
80010002-0701ffff
Numeric sensor
[NumericSensorElementName] going
low (lower non-critical) has asserted.
(CMOS Battery)
Explanation: This message is for the use case when an
implementation has detected a Lower Non-critical
sensor going low has asserted.
May also be shown as 800100020701ffff or
0x800100020701ffff
Severity: Warning
Alert Category: Warning - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0476
SNMP Trap ID: 13
Automatically notify Support: No
User response: Replace the system battery.
80010202-0701ffff
Numeric sensor
[NumericSensorElementName] going
low (lower critical) has asserted.
Explanation: This message is for the use case when an
implementation has detected a Lower Critical sensor
going low has asserted.
May also be shown as 800102020701ffff or
0x800102020701ffff
Severity: Error
Alert Category: Critical - Voltage
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 1
Automatically notify Support: Yes
User response: If the specified sensor is CMOS
battery, replace the system battery. If the specified
sensor is Planar 3.3V or Planar 5V, (trained technician
only) replace the system board. If the specified sensor
is Planar 12V, complete the following steps until the
problem is solved:
Check power supply n LED.
1.
2.
Remove the failing power supply.
3.
Follow actions in "Power Problems and Solving
Power Problems".
4.
(Trained technician only) Replace the system board.
(n = power supply number)
356
System x3550 M4 Type 7914: Installation and Service Guide
80010204-1d01ffff
Numeric sensor
[NumericSensorElementName] going
low (lower critical) has asserted. (Fan
1A/1B Tach)
Explanation: This message is for the use case when an
implementation has detected a Lower Critical sensor
going low has asserted.
May also be shown as 800102041d01ffff or
0x800102041d01ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Reseat the failing fan n, which is indicated by a lit
LED near the fan connector on the system board.
2.
Replace the failing fan. (n = fan number)
80010204-1d02ffff
Numeric sensor
[NumericSensorElementName] going
low (lower critical) has asserted. (Fan
2A/2B Tach)
Explanation: This message is for the use case when an
implementation has detected a Lower Critical sensor
going low has asserted.
May also be shown as 800102041d02ffff or
0x800102041d02ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Reseat the failing fan n, which is indicated by a lit
LED near the fan connector on the system board.
2.
Replace the failing fan. (n = fan number)
80010204-1d03ffff
Numeric sensor
[NumericSensorElementName] going
low (lower critical) has asserted. (Fan
3A/3B Tach)
Explanation: This message is for the use case when an
implementation has detected a Lower Critical sensor
going low has asserted.