free hit counter

Lenovo x3550 M4 Installation And Service Manual page 375

Hide thumbs Also See for x3550 M4:
Table of Contents

Advertisement

May also be shown as 800102041d03ffff or
0x800102041d03ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Reseat the failing fan n, which is indicated by a lit
LED near the fan connector on the system board.
2.
Replace the failing fan. (n = fan number)
80010204-1d04ffff
Numeric sensor
[NumericSensorElementName] going
low (lower critical) has asserted. (Fan
4A/4B Tach)
Explanation: This message is for the use case when an
implementation has detected a Lower Critical sensor
going low has asserted.
May also be shown as 800102041d04ffff or
0x800102041d04ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Reseat the failing fan n, which is indicated by a lit
LED near the fan connector on the system board.
2.
Replace the failing fan. (n = fan number)
80010204-1d05ffff
Numeric sensor
[NumericSensorElementName] going
low (lower critical) has asserted. (Fan
5A/5B Tach)
Explanation: This message is for the use case when an
implementation has detected a Lower Critical sensor
going low has asserted.
May also be shown as 800102041d05ffff or
0x800102041d05ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
80010204-1d04ffff • 80010701-0c01ffff
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Reseat the failing fan n, which is indicated by a lit
LED near the fan connector on the system board.
2.
Replace the failing fan. (n = fan number)
80010204-1d06ffff
Explanation: This message is for the use case when an
implementation has detected a Lower Critical sensor
going low has asserted.
May also be shown as 800102041d06ffff or
0x800102041d06ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Reseat the failing fan n, which is indicated by a lit
LED near the fan connector on the system board.
2.
Replace the failing fan. (n = fan number)
80010701-0c01ffff
Explanation: This message is for the use case when an
implementation has detected an Upper Non-critical
sensor going high has asserted.
May also be shown as 800107010c01ffff or
0x800107010c01ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1.
Reduce the temperature.
2.
Check the server airflow. Make sure that nothing is
blocking the air from coming into or preventing the
air from exiting the server.
Appendix A. Integrated management module II (IMM2) error messages
Numeric sensor
[NumericSensorElementName] going
low (lower critical) has asserted. (Fan
6A/6B Tach)
Numeric sensor
[NumericSensorElementName] going
high (upper non-critical) has asserted.
(Ambient Temp)
357

Advertisement

Table of Contents
loading

Table of Contents