80010701-2d01ffff • 80010901-1401ffff
80010701-2d01ffff
Numeric sensor
[NumericSensorElementName] going
high (upper non-critical) has asserted.
(PCH Temp)
Explanation: This message is for the use case when an
implementation has detected an Upper Non-critical
sensor going high has asserted.
May also be shown as 800107012d01ffff or
0x800107012d01ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0490
SNMP Trap ID: 12
Automatically notify Support: No
User response:
1.
Reduce the temperature.
2.
Check the server airflow. Make sure that nothing is
blocking the air from coming into or preventing the
air from exiting the server.
80010901-0c01ffff
Numeric sensor
[NumericSensorElementName] going
high (upper critical) has asserted.
(Ambient Temp)
Explanation: This message is for the use case when an
implementation has detected an Upper Critical sensor
going high has asserted.
May also be shown as 800109010c01ffff or
0x800109010c01ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Reduce the ambient temperature.
2.
Ensure the air baffle is installed correctly.
3.
Check the server airflow. Make sure that nothing is
blocking the air from coming into or preventing the
air from exiting the server.
80010901-1001ffff
Numeric sensor
[NumericSensorElementName] going
high (upper critical) has asserted. (PCI
Riser 1 Temp)
Explanation: This message is for the use case when an
360
System x3550 M4 Type 7914: Installation and Service Guide
implementation has detected an Upper Critical sensor
going high has asserted.
May also be shown as 800109011001ffff or
0x800109011001ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Reduce the ambient temperature.
2.
Ensure the air baffle is installed correctly.
3.
Check the server airflow. Make sure that nothing is
blocking the air from coming into or preventing the
air from exiting the server.
80010901-1002ffff
Numeric sensor
[NumericSensorElementName] going
high (upper critical) has asserted. (PCI
Riser 2 Temp)
Explanation: This message is for the use case when an
implementation has detected an Upper Critical sensor
going high has asserted.
May also be shown as 800109011002ffff or
0x800109011002ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0494
SNMP Trap ID: 0
Automatically notify Support: No
User response:
Reduce the ambient temperature.
1.
Ensure the air baffle is installed correctly.
2.
Check the server airflow. Make sure that nothing is
3.
blocking the air from coming into or preventing the
air from exiting the server.
80010901-1401ffff
Numeric sensor
[NumericSensorElementName] going
high (upper critical) has asserted. (CPU1
VR Temp)
Explanation: This message is for the use case when an
implementation has detected an Upper Critical sensor
going high has asserted.
May also be shown as 800109011401ffff or
0x800109011401ffff