free hit counter

Lenovo x3550 M4 Installation And Service Manual page 386

Hide thumbs Also See for x3550 M4:
Table of Contents

Advertisement

80070208-0a02ffff • 80070214-2201ffff
Automatically notify Support: No
User response:
Make sure that there are no obstructions, such as
1.
bundled cables, to the airflow from the
power-supply fan.
Use the IBM Power Configurator utility to ensure
2.
current system power consumption is under
limitation. For more information and to download
the utility, go to http://www-03.ibm.com/systems/
bladecenter/resources/powerconfig.html.
3.
Replace power supply n. (n = power supply
number)
80070208-0a02ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (PS 2 Therm Fault)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 800702080a02ffff or
0x800702080a02ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 4
Automatically notify Support: No
User response:
Make sure that there are no obstructions, such as
1.
bundled cables, to the airflow from the
power-supply fan.
Use the IBM Power Configurator utility to ensure
2.
current system power consumption is under
limitation. For more information and to download
the utility, go to http://www-03.ibm.com/systems/
bladecenter/resources/powerconfig.html.
3.
Replace power supply n. (n = power supply
number)
8007020f-2201ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (TXT ACM Module)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 8007020f2201ffff or
0x8007020f2201ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
368
System x3550 M4 Type 7914: Installation and Service Guide
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
If enabling TXT is not required, disable TXT from
the Setup Utility.
2.
If enabling TXT is required, verify that the TPM is
enabled and activated from the Setup Utility.
3.
If the problem remains, contact your service
representative.
8007020f-2582ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (I/O Resources)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 8007020f2582ffff or
0x8007020f2582ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID: 50
Automatically notify Support: No
User response: Complete the following step to solve
PCI I/O resource errors:
1.
Go to F1 Setup-> System Settings-> Device and
I/O ports-> PCI 64 bit Resource and choose enable.
80070214-2201ffff
Sensor [SensorElementName] has
transitioned to critical from a less severe
state. (TPM Lock)
Explanation: This message is for the use case when an
implementation has detected a Sensor transitioned to
critical from less severe.
May also be shown as 800702142201ffff or
0x800702142201ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0522
SNMP Trap ID:
Automatically notify Support: No
User response:
1.
Update the server firmware (see Recovering the
server firmware).

Advertisement

Table of Contents
loading

Table of Contents