800b0008-1301ffff • 800b010c-2581ffff
CIM Information: Prefix: PLAT and ID: 0536
SNMP Trap ID:
Automatically notify Support: No
User response: No action; information only.
800b0008-1301ffff
Redundancy
[RedundancySetElementName] has been
restored. (Power Unit)
Explanation: This message is for the use case when an
implementation has detected Redundancy was
Restored.
May also be shown as 800b00081301ffff or
0x800b00081301ffff
Severity: Info
Alert Category: Warning - Redundant Power Supply
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0561
SNMP Trap ID: 10
Automatically notify Support: No
User response: No action; information only.
800b0108-1301ffff
Redundancy Lost for
[RedundancySetElementName] has
asserted. (Power Unit)
Explanation: This message is for the use case when
Redundancy Lost has asserted.
May also be shown as 800b01081301ffff or
0x800b01081301ffff
Severity: Error
Alert Category: Critical - Redundant Power Supply
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 9
Automatically notify Support: No
User response:
Check the LEDs for both power supplies.
1.
Follow the actions in Power-supply LEDs.
2.
800b010a-1e81ffff
Redundancy Lost for
[RedundancySetElementName] has
asserted. (Fan Zone 1)
Explanation: This message is for the use case when
Redundancy Lost has asserted.
May also be shown as 800b010a1e81ffff or
0x800b010a1e81ffff
Severity: Error
372
System x3550 M4 Type 7914: Installation and Service Guide
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 11
Automatically notify Support: No
User response:
Make sure that the connectors on fan n are not
1.
damaged.
Make sure that the fan n connectors on the system
2.
board are not damaged.
Make sure that the fans are correctly installed.
3.
4.
Reseat the fans.
5.
Replace the fans. (n = fan number)
800b010a-1e82ffff
Redundancy Lost for
[RedundancySetElementName] has
asserted. (Fan Zone 2)
Explanation: This message is for the use case when
Redundancy Lost has asserted.
May also be shown as 800b010a1e82ffff or
0x800b010a1e82ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0802
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1.
Make sure that the connectors on fan n are not
damaged.
2.
Make sure that the fan n connectors on the system
board are not damaged.
3.
Make sure that the fans are correctly installed.
4.
Reseat the fans.
5.
Replace the fans. (n = fan number)
800b010c-2581ffff
Redundancy Lost for
[RedundancySetElementName] has
asserted. (Backup Memory)
Explanation: This message is for the use case when
Redundancy Lost has asserted.
May also be shown as 800b010c2581ffff or
0x800b010c2581ffff
Severity: Error
Alert Category: Critical - Memory
Serviceable: Yes