free hit counter

Lenovo x3550 M4 Installation And Service Manual page 416

Hide thumbs Also See for x3550 M4:
Table of Contents

Advertisement

806f020d-0401ffff • 806f020d-0404ffff
1.
Run the hard disk drive diagnostic test on drive n.
2.
Reseat the following components: a. Hard disk
drive b. Cable from the system board to the
backplane.
3.
Replace the following components one at a time, in
the order shown, restarting the server each time: a.
Hard disk drive. b. Cable from the system board to
the backplane. c. Hard disk drive backplane. (n =
hard disk drive number)
806f020d-0401ffff
Failure Predicted on drive
[StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive
1)
Explanation: This message is for the use case when an
implementation has detected an Array Failure is
Predicted.
May also be shown as 806f020d0401ffff or
0x806f020d0401ffff
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
SNMP Trap ID: 27
Automatically notify Support: Yes
User response:
1.
Run the hard disk drive diagnostic test on drive n.
2.
Reseat the following components: a. Hard disk
drive b. Cable from the system board to the
backplane.
3.
Replace the following components one at a time, in
the order shown, restarting the server each time: a.
Hard disk drive. b. Cable from the system board to
the backplane. c. Hard disk drive backplane. (n =
hard disk drive number)
806f020d-0402ffff
Failure Predicted on drive
[StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive
2)
Explanation: This message is for the use case when an
implementation has detected an Array Failure is
Predicted.
May also be shown as 806f020d0402ffff or
0x806f020d0402ffff
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
SNMP Trap ID: 27
398
System x3550 M4 Type 7914: Installation and Service Guide
Automatically notify Support: Yes
User response:
Run the hard disk drive diagnostic test on drive n.
1.
Reseat the following components: a. Hard disk
2.
drive b. Cable from the system board to the
backplane.
Replace the following components one at a time, in
3.
the order shown, restarting the server each time: a.
Hard disk drive. b. Cable from the system board to
the backplane. c. Hard disk drive backplane. (n =
hard disk drive number)
806f020d-0403ffff
Failure Predicted on drive
[StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive
3)
Explanation: This message is for the use case when an
implementation has detected an Array Failure is
Predicted.
May also be shown as 806f020d0403ffff or
0x806f020d0403ffff
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
SNMP Trap ID: 27
Automatically notify Support: Yes
User response:
Run the hard disk drive diagnostic test on drive n.
1.
Reseat the following components: a. Hard disk
2.
drive b. Cable from the system board to the
backplane.
Replace the following components one at a time, in
3.
the order shown, restarting the server each time: a.
Hard disk drive. b. Cable from the system board to
the backplane. c. Hard disk drive backplane. (n =
hard disk drive number)
806f020d-0404ffff
Failure Predicted on drive
[StorageVolumeElementName] for array
[ComputerSystemElementName]. (Drive
4)
Explanation: This message is for the use case when an
implementation has detected an Array Failure is
Predicted.
May also be shown as 806f020d0404ffff or
0x806f020d0404ffff
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes

Advertisement

Table of Contents
loading