SNMP Trap ID:
Automatically notify Support: No
User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory
fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions
for that error event and restart the server.
3.
Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory event. If no memory fault is recorded in
the logs and no DIMM connector error LED is lit,
you can re-enable the DIMM through the Setup
utility or the Advanced Settings Utility (ASU).
806f040c-2008ffff
[PhysicalMemoryElementName]
Disabled on Subsystem
[MemoryElementName]. (DIMM 8)
Explanation: This message is for the use case when an
implementation has detected that Memory has been
Disabled.
May also be shown as 806f040c2008ffff or
0x806f040c2008ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
1.
Make sure the DIMM is installed correctly.
2.
If the DIMM was disabled because of a memory
fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions
for that error event and restart the server.
3.
Check the IBM support website for an applicable
retain tip or firmware update that applies to this
memory event. If no memory fault is recorded in
the logs and no DIMM connector error LED is lit,
you can re-enable the DIMM through the Setup
utility or the Advanced Settings Utility (ASU).
806f040c-2009ffff
[PhysicalMemoryElementName]
Disabled on Subsystem
[MemoryElementName]. (DIMM 9)
Explanation: This message is for the use case when an
implementation has detected that Memory has been
Disabled.
May also be shown as 806f040c2009ffff or
0x806f040c2009ffff
Severity: Info
806f040c-2008ffff • 806f040c-200bffff
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
Make sure the DIMM is installed correctly.
1.
2.
If the DIMM was disabled because of a memory
fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions
for that error event and restart the server.
Check the IBM support website for an applicable
3.
retain tip or firmware update that applies to this
memory event. If no memory fault is recorded in
the logs and no DIMM connector error LED is lit,
you can re-enable the DIMM through the Setup
utility or the Advanced Settings Utility (ASU).
806f040c-200affff
Explanation: This message is for the use case when an
implementation has detected that Memory has been
Disabled.
May also be shown as 806f040c200affff or
0x806f040c200affff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0131
SNMP Trap ID:
Automatically notify Support: No
User response:
Make sure the DIMM is installed correctly.
1.
If the DIMM was disabled because of a memory
2.
fault (memory uncorrectable error or memory
logging limit reached), follow the suggested actions
for that error event and restart the server.
Check the IBM support website for an applicable
3.
retain tip or firmware update that applies to this
memory event. If no memory fault is recorded in
the logs and no DIMM connector error LED is lit,
you can re-enable the DIMM through the Setup
utility or the Advanced Settings Utility (ASU).
806f040c-200bffff
Explanation: This message is for the use case when an
Appendix A. Integrated management module II (IMM2) error messages
[PhysicalMemoryElementName]
Disabled on Subsystem
[MemoryElementName]. (DIMM 10)
[PhysicalMemoryElementName]
Disabled on Subsystem
[MemoryElementName]. (DIMM 11)
413