806f0413-2582ffff • 806f0507-2584ffff
memory event. If no memory fault is recorded in
the logs and no DIMM connector error LED is lit,
you can re-enable the DIMM through the Setup
utility or the Advanced Settings Utility (ASU). One
of the DIMMs :
806f0413-2582ffff
A PCI PERR has occurred on
system [ComputerSystemElementName].
(PCIs)
Explanation: This message is for the use case when an
implementation has detected a PCI PERR.
May also be shown as 806f04132582ffff or
0x806f04132582ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0232
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
Check the PCI LED.
2.
Reseat the affected adapters and riser cards.
Update the server firmware (UEFI and IMM) and
3.
adapter firmware. Important: Some cluster solutions
require specific code levels or coordinated code
updates. If the device is part of a cluster solution,
verify that the latest level of code is supported for
the cluster solution before you update the code.
4.
Remove both adapters.
5.
Replace the PCIe adapters.
6.
Replace the riser card.
806f0507-0301ffff
[ProcessorElementName] has a
Configuration Mismatch. (CPU 1)
Explanation: This message is for the use case when an
implementation has detected a Processor Configuration
Mismatch has occurred.
May also be shown as 806f05070301ffff or
0x806f05070301ffff
Severity: Error
Alert Category: Critical - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0062
SNMP Trap ID: 40
Automatically notify Support: No
User response:
1.
Check the CPU LED. See more information about
the CPU LED in Light path diagnostics.
418
System x3550 M4 Type 7914: Installation and Service Guide
2.
Check for a server firmware update. Important:
Some cluster solutions require specific code levels
or coordinated code updates. If the device is part of
a cluster solution, verify that the latest level of code
is supported for the cluster solution before you
update the code.
3.
Make sure that the installed microprocessors are
compatible with each other.
4.
(Trained technician only) Reseat microprocessor n.
5.
(Trained technician only) Replace microprocessor n.
(n = microprocessor number)
806f0507-0302ffff
[ProcessorElementName] has a
Configuration Mismatch. (CPU 2)
Explanation: This message is for the use case when an
implementation has detected a Processor Configuration
Mismatch has occurred.
May also be shown as 806f05070302ffff or
0x806f05070302ffff
Severity: Error
Alert Category: Critical - CPU
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0062
SNMP Trap ID: 40
Automatically notify Support: No
User response:
1.
Check the CPU LED. See more information about
the CPU LED in Light path diagnostics.
2.
Check for a server firmware update. Important:
Some cluster solutions require specific code levels
or coordinated code updates. If the device is part of
a cluster solution, verify that the latest level of code
is supported for the cluster solution before you
update the code.
3.
Make sure that the installed microprocessors are
compatible with each other.
4.
(Trained technician only) Reseat microprocessor n.
5.
(Trained technician only) Replace microprocessor n.
(n = microprocessor number)
806f0507-2584ffff
[ProcessorElementName] has a
Configuration Mismatch. (All CPUs)
Explanation: This message is for the use case when an
implementation has detected a Processor Configuration
Mismatch has occurred.
May also be shown as 806f05072584ffff or
0x806f05072584ffff
Severity: Error
Alert Category: Critical - CPU
Serviceable: Yes