Automatically notify Support: No
User response:
Make sure that the RAID adapter firmware and
1.
hard disk drive firmware are at the latest level.
Make sure that the SAS cable is connected
2.
correctly.
Replace the SAS cable.
3.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
806f050d-0404ffff
Array
[ComputerSystemElementName] is in
critical condition. (Drive 4)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
May also be shown as 806f050d0404ffff or
0x806f050d0404ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
Replace the hard disk drive that is indicated by a
6.
lit status LED.
806f050d-0405ffff
Array
[ComputerSystemElementName] is in
critical condition. (Drive 5)
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
May also be shown as 806f050d0405ffff or
0x806f050d0405ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
806f050d-0404ffff • 806f050d-0407ffff
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
3.
Replace the SAS cable.
4.
Check backplane cable connection.
5.
Replace the RAID adapter.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
806f050d-0406ffff
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
May also be shown as 806f050d0406ffff or
0x806f050d0406ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0174
SNMP Trap ID: 5
Automatically notify Support: No
User response:
1.
Make sure that the RAID adapter firmware and
hard disk drive firmware are at the latest level.
2.
Make sure that the SAS cable is connected
correctly.
Replace the SAS cable.
3.
Check backplane cable connection.
4.
Replace the RAID adapter.
5.
6.
Replace the hard disk drive that is indicated by a
lit status LED.
806f050d-0407ffff
Explanation: This message is for the use case when an
implementation has detected that an Array is Critical.
May also be shown as 806f050d0407ffff or
0x806f050d0407ffff
Severity: Error
Alert Category: Critical - Hard Disk drive
Serviceable: Yes
Appendix A. Integrated management module II (IMM2) error messages
Array
[ComputerSystemElementName] is in
critical condition. (Drive 6)
Array
[ComputerSystemElementName] is in
critical condition. (Drive 7)
429