free hit counter

Lenovo x3550 M4 Installation And Service Manual page 468

Hide thumbs Also See for x3550 M4:
Table of Contents

Advertisement

806f0a0c-200bffff • 806f0a0c-200effff
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-200bffff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 11)
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Detected.
May also be shown as 806f0a0c200bffff or
0x806f0a0c200bffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow, that the air baffles
are in place and correctly installed, and that the
server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-200cffff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 12)
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Detected.
May also be shown as 806f0a0c200cffff or
0x806f0a0c200cffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
450
System x3550 M4 Type 7914: Installation and Service Guide
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow, that the air baffles
are in place and correctly installed, and that the
server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-200dffff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 13)
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Detected.
May also be shown as 806f0a0c200dffff or
0x806f0a0c200dffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow, that the air baffles
are in place and correctly installed, and that the
server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-200effff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 14)
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Detected.
May also be shown as 806f0a0c200effff or
0x806f0a0c200effff
Severity: Error
Alert Category: Critical - Temperature