806f0a0c-2012ffff • 806f0a0c-2015ffff
806f0a0c-2012ffff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 18)
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Detected.
May also be shown as 806f0a0c2012ffff or
0x806f0a0c2012ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow, that the air baffles
are in place and correctly installed, and that the
server cover is installed and completely closed.
Make sure that ambient temperature is within the
2.
specifications.
If a fan has failed, complete the action for a fan
3.
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-2013ffff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 19)
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Detected.
May also be shown as 806f0a0c2013ffff or
0x806f0a0c2013ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow, that the air baffles
are in place and correctly installed, and that the
server cover is installed and completely closed.
452
System x3550 M4 Type 7914: Installation and Service Guide
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-2014ffff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 20)
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Detected.
May also be shown as 806f0a0c2014ffff or
0x806f0a0c2014ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow, that the air baffles
are in place and correctly installed, and that the
server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-2015ffff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 21)
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Detected.
May also be shown as 806f0a0c2015ffff or
0x806f0a0c2015ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No