User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow, that the air baffles
are in place and correctly installed, and that the
server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-2016ffff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 22)
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Detected.
May also be shown as 806f0a0c2016ffff or
0x806f0a0c2016ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow, that the air baffles
are in place and correctly installed, and that the
server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-2017ffff
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 23)
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Detected.
May also be shown as 806f0a0c2017ffff or
0x806f0a0c2017ffff
Severity: Error
Alert Category: Critical - Temperature
806f0a0c-2016ffff • 806f0a13-0301ffff
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow, that the air baffles
are in place and correctly installed, and that the
server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-2018ffff
Explanation: This message is for the use case when an
implementation has detected an Over Temperature
Condition for Memory that has been Detected.
May also be shown as 806f0a0c2018ffff or
0x806f0a0c2018ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0146
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow, that the air baffles
are in place and correctly installed, and that the
server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the
specifications.
3.
If a fan has failed, complete the action for a fan
failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a13-0301ffff
Explanation: This message is for the use case when an
implementation has detected a Bus Fatal Error.
May also be shown as 806f0a130301ffff or
0x806f0a130301ffff
Appendix A. Integrated management module II (IMM2) error messages
An Over-Temperature Condition
has been detected on the
[PhysicalMemoryElementName] on
Subsystem [MemoryElementName].
(DIMM 24)
A Fatal Bus Error has occurred on
system [ComputerSystemElementName].
(CPU 1 PECI)
453