CIM Information: Prefix: PLAT and ID: 0167
SNMP Trap ID: 5
Automatically notify Support: No
User response: No action; information only.
816f010d-0407ffff
The Drive
[StorageVolumeElementName] has been
enabled. (Drive 7)
Explanation: This message is for the use case when an
implementation has detected a Drive was Enabled.
May also be shown as 816f010d0407ffff or
0x816f010d0407ffff
Severity: Info
Alert Category: Critical - Hard Disk drive
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0167
SNMP Trap ID: 5
Automatically notify Support: No
User response: No action; information only.
816f010f-2201ffff
The System
[ComputerSystemElementName] has
recovered from a firmware hang.
(Firmware Error)
Explanation: This message is for the use case when an
implementation has recovered from a System Firmware
Hang.
May also be shown as 816f010f2201ffff or
0x816f010f2201ffff
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0187
SNMP Trap ID: 50
Automatically notify Support: No
User response: No action; information only.
816f0113-0301ffff
System
[ComputerSystemElementName] has
recovered from a bus timeout. (CPU 1
PECI)
Explanation: This message is for the use case when an
implemenation has detected that a system has
recovered from a Bus Timeout.
May also be shown as 816f01130301ffff or
0x816f01130301ffff
816f010d-0407ffff • 816f011b-0701ffff
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0225
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
(Trained technician only) Replace microprocessor n
(see Removing a microprocessor and heat sink and
Replacing a microprocessor and heat sink).
2.
If the problem persists and there is no other CPU
with the same error indication, replace the system
board.
3.
(Trained technician only) Replace the system board
(see Removing the system board and Replacing the
system board). (n = microprocessor number)
816f0113-0302ffff
Explanation: This message is for the use case when an
implemenation has detected that a system has
recovered from a Bus Timeout.
May also be shown as 816f01130302ffff or
0x816f01130302ffff
Severity: Info
Alert Category: Critical - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0225
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1.
(Trained technician only) Replace microprocessor n
(see Removing a microprocessor and heat sink and
Replacing a microprocessor and heat sink).
2.
If the problem persists and there is no other CPU
with the same error indication, replace the system
board.
3.
(Trained technician only) Replace the system board
(see Removing the system board and Replacing the
system board). (n = microprocessor number)
816f011b-0701ffff
Explanation: This message is for the use case when an
implementation has detected an Interconnect
Configuration was Repaired.
Appendix A. Integrated management module II (IMM2) error messages
System
[ComputerSystemElementName] has
recovered from a bus timeout. (CPU 2
PECI)
The connector
[PhysicalConnectorElementName]
configuration error has been repaired.
(Front USB)
479