4. Replace the operator information panel assembly.
5. Run the test again.
6. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
DSA CPU stress test results
The following messages can result when you run the CPU stress test.
089-000-000
CPU Stress Test Passed
Explanation: CPU Stress Test Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
v
IBM Support Website
Latest level of DSA
v
Latest level of BMC/IMM
v
089-801-000
CPU Stress Test Aborted
Explanation: CPU Stress Test Aborted. Internal
Program Error.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Turn off and restart the system.
2. Make sure that the DSA Diagnostic code is at the
latest level.
3. Run the test again.
4. Check system firmware level and upgrade if
necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component. The
latest level firmware for this component can be
found in reference to this system type at the IBM
Support website.
5. Run the test again.
6. If the system has stopped responding, turn off and
restart the system and then run the test again.
7. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related Links:
IBM Support Website
v
Latest level of DSA
v
089-000-000 • 089-803-000
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
Latest level of BMC/IMM
v
089-802-000
CPU Stress Test Aborted
Explanation: CPU Stress Test Aborted. System
resource unavailability error.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Turn off and restart the system.
2. Make sure that the DSA Diagnostic code is at the
latest level.
3. Run the test again.
4. Check system firmware level and upgrade if
necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component.
5. Run the test again.
6. If the system has stopped responding, turn off and
restart the system and then run the test again.
7. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related Links:
v
IBM Support Website
Latest level of DSA
v
Latest level of BMC/IMM
v
089-803-000
CPU Stress Test Aborted
Explanation: CPU Stress Test Aborted. Memory size is
insufficient to run the test. At least 1GB is required.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
Related Links:
IBM Support Website
v
v
Latest level of DSA
Appendix C. DSA diagnostic test results