free hit counter

Dsa Exa Port Ping Test Results; Dsa Hard Drive Test Results - Lenovo x3550 M4 Installation And Service Manual

Hide thumbs Also See for x3550 M4:
Table of Contents

Advertisement

401-000-000 • 217-000-000
IBM Support Website
v
Latest level of DSA
v

DSA EXA port ping test results

The following messages can result when you run the EXA port ping test.
401-000-000
EXA Port Ping Test Passed
Explanation: EXA Port Ping Test Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
401-801-000
EXA Port Ping Test Aborted
Explanation: EXA Port Ping Test Aborted. Unable to
get device base address.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Remove power cables, wait for 45 seconds,
reconnect and rerun the test.
2. Make sure that the scalability cable connections are
as per specification.
3. Make sure that DSA and BIOS/uEFI are at the latest
level.
4. If the problem remains, contact your
technical-service representative.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
401-802-000
EXA Port Ping Test Aborted
Explanation: EXA Port Ping Test Aborted. Port
connections may not be correct.
Severity: Warning

DSA hard drive test results

The following messages can result when you run the hard drive test.
217-000-000
HDD Test Passed
542
System x3550 M4 Type 7914: Installation and Service Guide
Latest level of BMC/IMM
v
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Remove power cables, wait for 45 seconds,
reconnect and rerun the test.
2. Make sure that the scalability cable connections are
as per specification.
3. Make sure that DSA and BIOS/uEFI are at the latest
level.
4. If the problem remains, contact your
technical-service representative.
Related Links:
v
IBM Support Website
Latest level of DSA
v
Latest level of BMC/IMM
v
401-901-001
EXA Port Ping Test Failed
Explanation: EXA Port Ping Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Remove power cables, wait for 45 seconds,
reconnect and rerun the test.
2. Make sure that the scalability cable connections are
as per specification.
3. Check scalability cables for loose connections.
4. Replace the scalability cable(s) for specified port(s).
5. If the problem remains, contact your
technical-service representative.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
Explanation: HDD Stress Test Passed.

Advertisement

Table of Contents
loading