in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related Links:
IBM Support Website
v
Latest level of DSA
v
v
Latest level of BMC/IMM
406-901-000
IANet:EEPROM Test Failed
Explanation: A failure was detected during the
EEPROM test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check component firmware level and upgrade if
necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related Links:
v
IBM Support Website
v
Latest level of DSA
Latest level of BMC/IMM
v
406-902-000
IANet:FIFO Test Failed
Explanation: A failure was detected during the FIFO
test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check component firmware level and upgrade if
necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component.
2. Rerun the test.
3. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
406-901-000 • 406-904-000
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
406-903-000
IANet:Interrupts Test Failed
Explanation: A failure was detected during the
Interrupt test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check component firmware level and upgrade if
necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component.
2. Rerun the test.
3. Check interrupt assignments in the PCI Hardware
section of the DSA Diagnostic Log. If the ethernet
device is sharing interrupts, if possible modify the
interrupt assignments using F1 Setup to assign a
unique interrupt to the device.
4. Rerun the test.
5. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
406-904-000
IANet:Loopback Test Failed
Explanation: A failure was detected during the
Loopback test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check the Ethernet cable for damage and ensure
correct cable type and attachment.
2. Check component firmware level and upgrade if
necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component.
3. Rerun the test.
Appendix C. DSA diagnostic test results
545