201-899-002 • 201-901-002
201-899-002
Standalone Memory Test Aborted
Explanation: Memory Diagnostics Test Aborted by
user.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
201-899-003
Standalone Memory Test Aborted
Explanation: Memory Diagnostics Test Aborted by
user.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
201-901-000
Standalone Memory Test Failed
Explanation: Memory Diagnostics Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Perform the actions mentioned one at a time and
try the test after each action.
2. If the problem remains, contact your
technical-service representative.
3. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reseat DIMM(s). Reconnect it
to power.
4. Make sure that DSA and BIOS/uEFI are at the latest
level.
5. Replace any DIMMS(s) mentioned in error, one by
one.
6. Make sure that all DIMMs are enabled in the
Configuration/Setup Utility program.
580
System x3550 M4 Type 7914: Installation and Service Guide
7. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
201-901-001
Standalone Memory Test Failed
Explanation: Memory Diagnostics Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Perform the actions mentioned one at a time and
try the test after each action.
2. If the problem remains, contact your
technical-service representative.
3. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reseat DIMM(s). Reconnect it
to power.
4. Make sure that DSA and BIOS/uEFI are at the latest
level.
5. Replace any DIMMS(s) mentioned in error, one by
one.
6. Make sure that all DIMMs are enabled in the
Configuration/Setup Utility program.
7. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related Links:
v
IBM Support Website
Latest level of DSA
v
Latest level of BMC/IMM
v
201-901-002
Standalone Memory Test Failed
Explanation: Memory Diagnostics Test Failed.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Perform the actions mentioned one at a time and
try the test after each action.
2. If the problem remains, contact your
technical-service representative.