Latest level of DSA
v
Latest level of BMC/IMM
v
215-902-000
Optical Drive Test Failed
Explanation: Optical Drive Test Failed. Read
miscompare.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Insert a new CD or DVD into the drive and wait for
15 seconds for the media to be recognized. Rerun
the test.
2. Check the drive cabling for loose or broken
connections at both ends or damage to the cable.
Replace the cable if damage is present.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
215-903-000
Optical Drive Test Aborted
DSA system management test results
The following messages can result when you run the system management test.
166-000-001
IMM I2C Test Passed
Explanation: IMM I2C Test Passed.
Severity: Event
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
IBM Support Website
v
Latest level of DSA
v
Latest level of BMC/IMM
v
166-801-001
IMM I2C Test Aborted
Explanation: IMM returned incorrect response length.
Severity: Warning
Serviceable: Yes
215-902-000 • 166-802-001
Explanation: Optical Drive Test Aborted. Could not
access the device.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Insert a new CD or DVD into the drive and wait for
15 seconds for the media to be recognized. Rerun
the test.
2. Check the drive cabling for loose or broken
connections at both ends or damage to the cable.
Replace the cable if damage is present.
3. Run the test again.
4. Check system firmware level and upgrade if
necessary.The installed firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component.
5. Run the test again.
6. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related Links:
v
IBM Support Website
Latest level of DSA
v
Latest level of BMC/IMM
v
Recoverable: No
Automatically notify Support: No
User response: Perform the actions mentioned one at
a time and try the test after each action:
1. Turn off the system and disconnect it from power.
Wait for 45 seconds. Reconnect it to power.
2. Make sure that DSA and BMC/IMM are at the
latest level.
Related Links:
v
IBM Support Website
Latest level of DSA
v
Latest level of BMC/IMM
v
166-802-001
IMM I2C Test Aborted
Explanation: Test cannot be completed for unknown
reason.
Severity: Warning
Appendix C. DSA diagnostic test results
587