Page 1
Digital Time Switch Model: NTT06 24 Hour General Purpose Digital Timer Model: NTT07 7 Day General Purpose Digital Timer...
Page 2
It can control outputs of up to 16A which makes it suitable for domestic immersion heaters. The nTT06/7 comes with a link in place which can be removed to provide volt free contacts if required, making it suitable for a wider range of switching applications.
7 days (24 hour operation), 5 weekdays 2 weekend days, or any individual day (7 day operation). For the nTT06, 24 hour programming is the only option. Advance feature advances to next programmed operation.
Page 4
Note: the NTT06/7 is supplied with a wire link in place. This should not be removed unless volt free contacts are required. The terminals are marked as follows: E Earth continuity. N neutral supply. L Live supply. 1 Live Input for volt free output (if required, if not, leave wire link in place).
5. Reset: The time switch must be reset before programming for the first time, or after subsequent discharge for more than 5 days, and following a 4 hour period of charging. Press Rst using a pointed object, eg: a pencil. The display will show all the segments, and then clear to show: Use the Adv/ovr button to change between on and off for the automatic...
Page 6
Use the Adv/ovr or boost button to adjust the hour to the correct hour. Press Time to set the hour, and then the time will show the minutes. The hour is a 24 hour clock. Use the Adv/ovr or boost button to adjust the minutes to the correct minutes.
Page 7
Individual day – Mo followed automatically in programming by each of the other days. For the nTT06, Mo Tu We Th Fr Sa Su is the only option. once the desired day grouping is selected, press Prg to move onto programming on/oFF times. The display will show Prog 1, with dashes for the hours and minutes.
Page 8
Press Prg to change to programme 1 oFF time. Press Prg to scroll through programme 2 on, programme 2 oFF, programme 3 on, programme 3 oFF, programme 4 on and programme 4 oFF, adding in times as required. If times are not required, just leave the dashes in place, and scroll past that programme.
Page 9
8.2 Programming across midnight: Enter the required programme on time. Enter the programme oFF time as 00:00 Enter the first programme on time for the next day as 00:00 Enter the required programme oFF time. Note: for 24 hour the on period for programme 1 must start 00:00.
Page 10
10. Advance/Override: In operating mode Adv/ovr advances the programme to the next change. If the output is oFF, it will change the output to on, until the next programmed off time. If the output is on, it will change the output to oFF, until the next programmed on time.
Switch type: 16A relay Volt free contact: Yes, if wire link is removed Contact type: normally open and normally closed Power on light: output Light: Time period: 24 Hr nTT06, 7 day nTT07. Note: Product not suitable for discharge lighting.
Page 12
3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge.