3. SPECIFICATIONS OF ELECTRICAL PARTS
3-1. RAC-18GE2B/18G2B/18G2L
No.
Parts name
1
Compressor
2
Fan motor
3
Auto louver motor
Room thermostat
(RAC-18GE2B)
4
Room thermostat
(RAC-18G-AR/18G2B/
18G2L)
Selector switch
(RAC-18GE2B)
5
Selector switch
(RAC-18G-AR/18G2B/
18G2L)
Running
for fan motor
6
capacitor
for compressor
Auto louver switch
7
Heater (RAS-18GE2B)
8
3-2. RAC-18G-AR
Different points from above model show below and another specifications are the same as above.
No.
Parts name
1
Compressor
2
Fan motor
Running
for fan motor
3
capacitor
for compressor
Code
Output (Rated) 1,500W, 2 poles, Single phase, 208/230V, 60Hz
RM6520GPH96
Winding resistance (Ω)
(at 20°C)
Output (Rated) 150W, 6 poles, Single phase, 220-230V, 60Hz
Winding resistance (Ω)
FG-230-150B
(at 20°C)
Output (Rated) 3W or less, 8 poles, Single phase, 220-240V, 50/60Hz
50SM16-54S
Winding resistance (kΩ) (at 20°C) 10.5
Differential 2°C
YTB-T321
Rated current 20A (at 250V)
Closing current 80A (at 250V)
Differential 2°C
B-A106
Rated current 25A
Closing current 90A
Rated current 3A (at 250V) between terminal 1-2, 3-4, 9-10
2137
Rated current 25A (at 250V) between terminal
Closing current 100A (at 250V) between terminal
Rated current 3A (at 250V) between terminal 1-2, 1-3
2105B
Rated current 25A (at 250V) between terminal 5-6, 1-4
DS45150BPQD
5µF, 450V
50µF, 440V
RS44B506U0218S
3019B-W
Reated AC current, closing and cut-off current 250V, 3A
3.5kW, Thermal relay 60 ± 3°C OFF, 45 ± 5°C ON
HG-2235
Thermal fuse 85 °C ON
Code
Output (Rated) 1,500W, 2 poles, Single phase, 230V, 50Hz
RM6523GNHE96
Winding resistance (Ω)
(at 20°C)
Output (Rated) 145W, 6 poles, Single phase, 220-240V, 50Hz
FG-240-145A
Winding resistance (Ω)
(at 20°C)
DS441805BPQJ
8µF , 440V
60µF , 440V
RS44B606U0220S
– 4 –
FILE NO. SVM-06049
Specifications
Red-Black
1.029
Red-Black
22.06
}
5-6, 11-12
5-6, 11-12
Specifications
Red-Black
1.194
Red-Black
34.88
White-Black
1.841
White-Black
37.07
White-Black
2.576
White-Black
27.12