Professional LCDs User Manual Version 1.04 The use of diagrams and illustrations in the manual for reference only, actual product may be different. Product design and specifications are subject to change without notice...
Contents Safety Precautions................................3 Important Safety Information ............................4 Declaration of Conformity .............................6 Getting Started................................7 Contents..................................7 Installing and Replacing Remote Control Batteries ....................8 Installation..................................9 Mounting ...................................9 Connecting To a Power Source..........................12 Connecting an External Video Source........................12 Connecting Multiple Displays for Video Wall Applications ..................13 Connector Positions..............................14 Input / Output Terminals ............................15 Operating Instructions..............................16...
Page 3
Digital RGB Input (DVI-D): DVI..........................23 RS-232 Output ................................24 RS-232 Input................................24 Troubleshooting ................................25 Recycling and Energy Information..........................26 Material Contents Declaration ............................27 Limited Warranty.................................28 DS651LT4 User Manual...
Safety Precautions CAUTION Do not install display in a wet environment or place anything on the top of the display filled with liquid, such as vase or beverage. Do not install near flammable objects, such as gasoline or other volatile liquids. Do not install near any heat sources such as radiators or other heating devices.
Please clean the backside of the LCD at least once a month to remove dust and other particles. Unplug the LCD immediately and contact a DynaScan certified service professional as soon as possible when any of the following situations occurs: Damaged power cord or power plug.
Page 6
Cleaning the Panel Use a soft, lint-free cloth to gently wipe dust off the screen panel. Do not use any hard material to wipe the panel. Do not poke the panel with your hand or any sharp object (such as a pen or a nail) or exert excessive pressure to the panel to prevent damage to the panel.
We hereby certify that the Professional LCD DS651LT4 is in compliance with Low Voltage Directive 2006/95/EC Electromagnetic Compatibility Directive 2004 /108 /EC IEC60950-1:2005+A1(2 Edition) EN60950-1:2006+A1:2010 EN55022:2006+A1:2007 Class A EN61000-3-2:2006+A1:2009+A2:2009 EN61000-3-3:2008 EN55024:1998+A1:2001+A2:2003 EN61000-4-2:2009 EN61000-4-3:2006+A1:2008+A2:2010 EN61000-4-4:2010 EN61000-4-5:2006 EN61000-4-6:2009 EN61000-4-8:2010 DynaScan Technology, Inc. EN61000-4-11:2004 EN61000-4-11:2004 DS651LT4 User Manual...
Getting Started Contents Confirm the accessories below are included with the display. If any item is missing, please contact your dealer. The color and shape of the accessories may vary by product. • DS651LT4 Professional LCD • Power cable x1 pcs •...
Installing and Replacing Remote Control Batteries 1. Open the battery compartment cover. 2. Insert 2 new AAA batteries. 3. Close the battery compartment cover. Warning: • Incorrect usage of batteries may cause leakage or explosion. • Pay attention to the polarity when installing batteries. •...
Installation The LCD must be properly installed using a wall mount. Incorrect installation may cause injury or damage the equipment. Product warranty does not cover damages caused by improper installation and DynaScan shall not be held responsible in such incident.
Page 11
Unit: [inch] Orientation When used in the portrait orientation, the LCD should be rotated clockwise such that the left edge becomes the top edge. DS651LT4 User Manual...
Page 12
Installation Location The ceiling or the wall must have enough strength to support the LCD and its accessories. Do not install in a location with strong vibrations or is dusty. Do not install near the building’s main electric panel. Do not install at a location where the LCD can be easily removed by the general public. When installed in an alcove, leave at least 10cm (4”) of space around the LCD to ensure proper ventilation.
Connecting To a Power Source Using the power cable provided, insert the female connector into the back of the display as shown in the diagram below. Connect the male end of the power cable to a 100-240 volt, 50 / 60Hz AC power outlet. Insert the plug completely into the socket.
Note: The maximum number of DS651LT4’s in a Video Wall is 36 (6 × 6). Note: The DynaScan “Display Manager” application is required to be installed on the PC in order to use the External Control feature.
Input / Output Terminals ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 1 RS-485 (IN): RS485 control function for the daisy chain application. ○ ○ ○ ○ 2 RS-232 (IN): RS232C network input connection for the use of remote control from computer. ○...
Operating Instructions Powering On/Off the Display To turn on/off the display, press the power switch on the back of the display as shown in the diagram below. NOTE: the remote control only works when the main switch is in the ON position. Using the Remote Control 100°...
Page 18
Using the Remote Control (cont.) Color and shape may vary by model. ITEM DESCRIPTION POWER Power On / Off MENU OSD On / Off Move the cursor up or change the setting of the selected item LEFT Exit the current selection RIGHT Select the highlighted item DOWN...
Using the Rear Panel Controls ITEM DESCRIPTION MENU OSD On / Off Move the cursor up or change the setting of the selected item DOWN Move the cursor down or change the setting of the selected item LEFT Exit the current selection RIGHT Select the highlighted item DS651LT4 User Manual...
Navigating the On Screen Display (OSD) Menu Press the MENU button on either the real panel control or remote control to display the OSD. Use the navigation arrows to select and adjust menu items. FACTORY ITEM DESCRIPTION DEFAULT Change the orientation of the Menu. The Menu can be DISPLAY MODE LAN.
Page 21
Note: When disabled, the remote control function can be enabled again from the control panel on the Signage or through the DynaScan “Display Manager” application. When in Power Save Mode, RS-232 controls do not function. Only [Main Power Switch] on the display or...
RS-232 Output PIN No. NAME connected to 7&8 connected to 6 connected to 4 connected to 1&8 connected to 1&7 RS-232 Input PIN No. NAME connected to 7&8 connected to 6 connected to 4 connected to 1&8 connected to 1&7 DS651LT4 User Manual...
Check whether the RS-232 cable is connected properly. • remotely via RS-232. Check whether the Ethernet crossover cable is connected properly. If you are still having trouble with your DynaScan DS² Professional LCD, contact your dealer or DynaScan directly for more assistance. DS651LT4 User Manual...
Recycling and Energy Information DynaScan is firmly committed to its environmental protection efforts and we believe that reducing our products’ impact on the environment is of the utmost importance. We are dedicated to meet the latest environmental protection regulations. Energy usage...
Material Contents Declaration Hazardous Substances Hexavalent Polybrominated Polybromodiphenyl Part Name Lead Mercury Cadmium Chromium Biphenyls Ethers PBDE PCBA CHASSIS ACCESSORY PACKAGE “O” indicates that the level of the specified chemical substance is less than the threshold level specified in the standards of SJ/T-11363-2006 and EU 2005/618/EC.
DynaScan and its Authorized Service Providers are not liable for any damage to or loss of data or other information stored on any media, or any non-DynaScan product or part not covered by this warranty. This warranty does not apply: (a) to damage caused by natural disasters, accident, abuse, misuse, misapplication, neglect;...
Page 30
PROGRAM OR DATA STORED IN OR USED WITH DYNASCAN PRODUCTS, AND ANY FAILURE TO MAINTAIN THE CONFIDENTIALITY OF DATA STORED ON THE PRODUCT. DYNASCAN SPECIFICALLY DOES NOT REPRESENT THAT IT WILL BE ABLE TO REPAIR ANY PRODUCT UNDER THIS WARRANTY OR MAKE A PRODUCT EXCHANGE WITHOUT RISK TO OR LOSS OF PROGRAMS OR DATA.