free hit counter

IBM 6C1 Service Manual page 149

Pseries 610
Table of Contents

Advertisement

Table 3. Firmware Error Codes. (continued)
Error Code Description
28030006 Processor frequency measurement error
28A00040 Power supply/fan errors
28A00050 Power supply failure
29000002 Keyboard/mouse controller failed self-test. Replace the system board.
29A00003 Keyboard not present/detected.
Action / Possible Failing FRU
1. Verify that the current level of the
system firmware is installed.
2. Replace the processor card
Location: P1-C1
Location: P1-C2
3. Replace system board.
Location: P1
(See note 3 on page 115.)
Replacing the battery does not
correct this error condition.
Check the following:
v Ensure the I/O and media fans are
properly connected to the system
board.
v Ensure the processor fan is
properly connected to the processor
card.
v Reseat all suspected fans
connectors.
v Look for obstructions that may
prevent the fans from normal
operations. (For example, a cable
caught in the fan, preventing it from
spinning.)
v Replace any suspected fans that
may cause this error.
v If after replacing the suspected
fans, the problem still exists:
– Replace the processor card for a
failing processor fan.
– Replace the system board
Location: P1
(See note 3 on page 115.)
1. Replace the power supply
specified by the location code.
2. Replace the power backplane.
Location: P3
Location: P1
(See note 3 on page 115.)
1. Keyboard
2. Replace the system board.
Location: P1
(See note 3 on page 115.)