Table 3. Firmware Error Codes. (continued)
Error Code Description
2BA00012 Service processor reports self-test failure. 1. Unplug the system power cable
2BA00013 Service processor reports bad NVRAM
CRC.
2BA00014 Service processor reports bad service
processor firmware.
2BA00017 Service processor reports bad or low
battery.
2BA00018 EPOW test failure.
2BA00019 IRQ13 test failure.
2BA00024 Service processor reports bad power
controller firmware.
2BA00040 Service processor reports service
processor VPD module not present.
2BA00041 Service processor VPD is corrupted.
Action / Possible Failing FRU
and wait until the system power
indicator remains off and the
operator panel is blank.
2. Plug the system power cable back
in and retry the operation.
3. Replace the system board.
Location: P1
(See note 3 on page 115.)
1. If problem persists, replace
battery.
Location: P1-V2
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
Use service processor firmware
diskette to reprogram firmware.
1. Replace the battery.
Location: P1-V2
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
Replace the system board.
Location: P1
(See note 3 on page 115.)
Replace the system board.
Location: P1
(See note 3 on page 115.)
Use the system firmware diskette to
reprogram the system firmware.
1. Use the service processor
firmware diskette to reprogram the
service processor firmware.
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
1. Use the service processor
firmware diskette to reprogram the
service processor firmware.
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
Chapter 5. Error Code to FRU Index
133