Table 3. Firmware Error Codes. (continued)
Error Code Description
40110010 Current sharing fault detected in power
40110011 DC_GOOD fault detected in main power
40110013 Only one power supply is present; two
40110014 Overcurrent detected on 5 volt line in
40111002 Unknown power problem detected.
146
Service Guide
supply main enclosure
supply enclosure
are required
power supply main enclosure
Action / Possible Failing FRU
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Reseat the power supplies
3. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Reseat the power supplies
3. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
Install an additional power supply. Two
power supplies are required.
1. If a location code is displayed with
this error code, replace the part at
that location.
2. Look at the service processor error
log for more error information.
3. Reseat the power supplies
4. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
1.
If a location code is displayed with
this error code, replace the part at
that location.
2. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3