Table 3. Firmware Error Codes. (continued)
Error Code Description
40112065 Critically low 2.5 V reading detected
40112066 Critically high 2.5 V reading detected
40112082 Low 5.0 voltage reading detected
40112092 Low 3.3 V reading detected
40112093 Low 2.5 V reading detected
Action / Possible Failing FRU
1. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the processor cards.
Location: P1-C1
Location: P1-C2
1. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the processor cards.
Location: P1-C1
Location: P1-C2
1. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the processor cards.
Location: P1-C1
Location: P1-C2
1. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the system board.
Location: P1
(See note 3 on page 115.)
1. Replace the power supplies
one-at-a-time.
Location: P3-V1
Location: P3-V2
Location: P3-V3
2. Replace the processor cards.
Location: P1-C1
Location: P1-C2
Chapter 5. Error Code to FRU Index